Fluorobenzene as new working fluid for high-temperature heat pumps and organic Rankine cycles: Energy analysis and thermal stability test

• Fluorobenzene is proposed as working fluid for high-temperature heat pumps and ORC. • Thermal stability of the fluid is tested with improved method and chemical analysis. • The presence of non-condensable gases removal system is simulated during the test. • Excellent stability is found as annual degradation is lower than 4 % at 350 °C. • At 180 °C heat sink temperature, COP of 3.25 is achieved for 100 °C temperature lift. Industrial high-temperature heat pumps and Organic Rankine Cycles play a pivotal role in reducing CO 2 emissions of the industrial sector. While several eco-friendly refrigerants have been explored for subcritical heat pumps below 150 °C, above this threshold only a few fluids can be adopted. In this article, fluorobenzene (C 6 H 5 F) is proposed for the first time as a versatile working fluid suitable for both HTHP and ORC systems. Notably, it possesses a near-zero Global Warming Potential, null Ozone Depletion Potential, low cost, and low toxicity. The thermo-chemical stability of fluorobenzene is experimentally investigated with an advanced procedure, simulating the presence of the non-condensable-gases removal system in real plant operating conditions. The yearly rate of unimolecular decomposition is estimated less than 4 % at 350 °C, and even after 400 h of thermal stress no decomposition products have been detected in the liquid phase through Fourier Transform Infrared Spectroscopy. In a direct heat exchange case study, coupled with exhaust gases at 390 °C, fluorobenzene achieves a net power production higher than other commercial fluids adopted in high-temperature units. In subcritical two-stage throttling heat pump condensing at 180 °C fluorobenzene shows a good Coefficient of Performance of 3.25 at 100 °C temperature lift.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2024-09-16
DOI
https://doi.org/10.1016/j.enconman.2024.119023
Citations
11
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
2.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fluorobenzene as new working fluid for high-temperature heat pumps and organic Rankine cycles: Energy analysis and thermal stability test

Michele Doninelli, Ivano Alessandri, Costante Mario Invernizzi, Gioele Di Marcoberardino et al.
11 citations
Energy Conversion and Management
Refrigeration and Air Conditioning Technologies
2.34
article

Fluorobenzene as new working fluid for high-temperature heat pumps and organic Rankine cycles: Energy analysis and thermal stability test

Michele Doninelli, Ivano Alessandri, Costante Mario Invernizzi, Gioele Di Marcoberardino, Paolo Iora
article en
11 citations

Abstract

• Fluorobenzene is proposed as working fluid for high-temperature heat pumps and ORC. • Thermal stability of the fluid is tested with improved method and chemical analysis. • The presence of non-condensable gases removal system is simulated during the test. • Excellent stability is found as annual degradation is lower than 4 % at 350 °C. • At 180 °C heat sink temperature, COP of 3.25 is achieved for 100 °C temperature lift. Industrial high-temperature heat pumps and Organic Rankine Cycles play a pivotal role in reducing CO 2 emissions of the industrial sector. While several eco-friendly refrigerants have been explored for subcritical heat pumps below 150 °C, above this threshold only a few fluids can be adopted. In this article, fluorobenzene (C 6 H 5 F) is proposed for the first time as a versatile working fluid suitable for both HTHP and ORC systems. Notably, it possesses a near-zero Global Warming Potential, null Ozone Depletion Potential, low cost, and low toxicity. The thermo-chemical stability of fluorobenzene is experimentally investigated with an advanced procedure, simulating the presence of the non-condensable-gases removal system in real plant operating conditions. The yearly rate of unimolecular decomposition is estimated less than 4 % at 350 °C, and even after 400 h of thermal stress no decomposition products have been detected in the liquid phase through Fourier Transform Infrared Spectroscopy. In a direct heat exchange case study, coupled with exhaust gases at 390 °C, fluorobenzene achieves a net power production higher than other commercial fluids adopted in high-temperature units. In subcritical two-stage throttling heat pump condensing at 180 °C fluorobenzene shows a good Coefficient of Performance of 3.25 at 100 °C temperature lift.

Energy Conversion and ManagementVol. 321
University of Brescia (IT)
Affordable and clean energy
Openalex Percentile: Top 12%
Refrigeration and Air Conditioning Technologies
2.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.