Enhancing of hydroquinone and catechol oxidation using a graphite and graphene composite polymer modified paste electrode

An innovative electrochemical redox response of hydroquinone (HQN) and catechol (CCL) was analysed using a bare graphite and graphene composite paste electrode (BGGCPE) and polymerised L-leucine modified graphite and graphene composite paste electrode (LCN-MGGCPE) was successfully developed in 0.2 M phosphate buffer solution (PBS) with pH 6.0 at a 0.1 V/s scan rate. Fabricated electrode using simple and cost-effective method, the polymerised LCN-MGGCPE surface shows more electrochemical activity, sensitivity and selectivity towards the determination for HQN and CCL. Cyclic voltammetry (CV), linear sweep voltammetry (LSV), Differential pulse voltammetry (DPV), and electrochemical impudence spectroscopy (EIS) were utilised as analytical techniques while LCN-MGGCPE and BGGCPE surface characterisation were studied using a scanning electron microscopy (SEM) technique. LCN-MGGCPE exhibited superior electrochemical activity compared to BGGCPE towards the oxidation responses of both HQN and CCL. Additionally, the effect of pH studies, scan rate change for HQN, and concentration change of analyte molecule were examined, with the 0.025 to 0.500 V/s scan rate varied and revealing an adsorption-controlled process. The concentration changes of CVs methods ranged from 0.2 to 320 μM, DPVs ranged from 0.2 to 1100 μM and LSVs ranged from 0.2 to 850 μM, the calculated a limit of detection (LOD) of CV, DPV, and LSV, is 0.020 μM, 0.026 μM, and 0.011 μM and a limit of quantification (LOQ) of 0.068 μM, 0.088 μM, and 0.035 μM. The electrochemically developed LCN-MGGCPE shows good reproducibility, repeatability, stability, sensitivity and simultaneous analysis of analyte molecules were studied. This study presents a promising pathway for the growth of effective sensors for the determination of HQN in medicinal and water sample applications.

Authors

Institutions

Publication Details

Journal
International Journal of Environmental & Analytical Chemistry
Published
2024-09-23
DOI
https://doi.org/10.1080/03067319.2024.2404534
Citations
7
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing of hydroquinone and catechol oxidation using a graphite and graphene composite polymer modified paste electrode

Narges Ataollahi, B. Kanthappa, J. G. Manjunatha, Tahani Mazyad Almutairi
7 citations
International Journal of Environmental & Analytical Chemistry
Electrochemical sensors and biosensors
1.46
article

Enhancing of hydroquinone and catechol oxidation using a graphite and graphene composite polymer modified paste electrode

Narges Ataollahi, B. Kanthappa, J. G. Manjunatha, Tahani Mazyad Almutairi
article en
7 citations

Abstract

An innovative electrochemical redox response of hydroquinone (HQN) and catechol (CCL) was analysed using a bare graphite and graphene composite paste electrode (BGGCPE) and polymerised L-leucine modified graphite and graphene composite paste electrode (LCN-MGGCPE) was successfully developed in 0.2 M phosphate buffer solution (PBS) with pH 6.0 at a 0.1 V/s scan rate. Fabricated electrode using simple and cost-effective method, the polymerised LCN-MGGCPE surface shows more electrochemical activity, sensitivity and selectivity towards the determination for HQN and CCL. Cyclic voltammetry (CV), linear sweep voltammetry (LSV), Differential pulse voltammetry (DPV), and electrochemical impudence spectroscopy (EIS) were utilised as analytical techniques while LCN-MGGCPE and BGGCPE surface characterisation were studied using a scanning electron microscopy (SEM) technique. LCN-MGGCPE exhibited superior electrochemical activity compared to BGGCPE towards the oxidation responses of both HQN and CCL. Additionally, the effect of pH studies, scan rate change for HQN, and concentration change of analyte molecule were examined, with the 0.025 to 0.500 V/s scan rate varied and revealing an adsorption-controlled process. The concentration changes of CVs methods ranged from 0.2 to 320 μM, DPVs ranged from 0.2 to 1100 μM and LSVs ranged from 0.2 to 850 μM, the calculated a limit of detection (LOD) of CV, DPV, and LSV, is 0.020 μM, 0.026 μM, and 0.011 μM and a limit of quantification (LOQ) of 0.068 μM, 0.088 μM, and 0.035 μM. The electrochemically developed LCN-MGGCPE shows good reproducibility, repeatability, stability, sensitivity and simultaneous analysis of analyte molecules were studied. This study presents a promising pathway for the growth of effective sensors for the determination of HQN in medicinal and water sample applications.

International Journal of Environmental & Analytical ChemistryVol. 105(17)
Mangalore University (IN), University of Trento (IT), King Saud University (SA)
Openalex Percentile: Top 18%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.