Factors affecting distribution of dose in horizontal direction during irradiation

Recording and managing the dose of x-rays in an x-ray machine is an important part of the data. In addition, recording and managing radiation dose data in x-ray devices plays an important role in providing transparency of radiation dose to medical staff and patients by quantifying the radiation dose data. Four mobile diagnostic X-ray units were used to analyze the dose by spatial location. The dose distribution by location was analyzed by identifying and analyzing the dose by angle for both image intensifier and flat panel detector types. The three-dimensional space of the radiation area consisted of 27 sides, and the structure of the space was assumed to be horizontal X, Y, and Z sides and vertical A, B, and C sides, and the dose analysis was performed at the assumed position. On the longitudinal side, the highest dose tissue (highest μSv/min) is B_Center : (R.B.M, Colon, Lung, Stomach, Breasts, Remainder of body) - 330.404 μSv/min, and the lowest dose tissue (lowest μSv/min) is 0.002 μSv/min on the (Skin, Bone surface, Salivary glands, Brain) side at C_270°. The findings from diagnostic X-ray devices have emphasized the importance of managing radiation exposure when using the devices and may raise questions about the management of radiation protection measures to protect the health of healthcare personnel and patients. This can be expected to advance the organization of the use of radiation devices in a safe healthcare environment. A system for managing data will be useful as an indicator to guide medical staff using the equipment and patients participating in procedures and surgeries where they can minimize their dose and avoid harm.

Authors

Institutions

Publication Details

Journal
Edelweiss Applied Science and Technology
Published
2024-09-21
DOI
https://doi.org/10.55214/25768484.v8i5.1883
Primary Topic
Radiation Effects and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors affecting distribution of dose in horizontal direction during irradiation

C.Y. Cho, J.-H. Kim, GeonUk Kang
Edelweiss Applied Science and Technology
Radiation Effects and Dosimetry
article

Factors affecting distribution of dose in horizontal direction during irradiation

C.Y. Cho, J.-H. Kim, GeonUk Kang
article en

Abstract

Recording and managing the dose of x-rays in an x-ray machine is an important part of the data. In addition, recording and managing radiation dose data in x-ray devices plays an important role in providing transparency of radiation dose to medical staff and patients by quantifying the radiation dose data. Four mobile diagnostic X-ray units were used to analyze the dose by spatial location. The dose distribution by location was analyzed by identifying and analyzing the dose by angle for both image intensifier and flat panel detector types. The three-dimensional space of the radiation area consisted of 27 sides, and the structure of the space was assumed to be horizontal X, Y, and Z sides and vertical A, B, and C sides, and the dose analysis was performed at the assumed position. On the longitudinal side, the highest dose tissue (highest μSv/min) is B_Center : (R.B.M, Colon, Lung, Stomach, Breasts, Remainder of body) - 330.404 μSv/min, and the lowest dose tissue (lowest μSv/min) is 0.002 μSv/min on the (Skin, Bone surface, Salivary glands, Brain) side at C_270°. The findings from diagnostic X-ray devices have emphasized the importance of managing radiation exposure when using the devices and may raise questions about the management of radiation protection measures to protect the health of healthcare personnel and patients. This can be expected to advance the organization of the use of radiation devices in a safe healthcare environment. A system for managing data will be useful as an indicator to guide medical staff using the equipment and patients participating in procedures and surgeries where they can minimize their dose and avoid harm.

Edelweiss Applied Science and TechnologyVol. 8(5)
Eulji University (KR), Sungkyunkwan University (KR)
Openalex Percentile: Top 81%
Radiation Effects and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Factors affecting distribution of dose in horizontal direction during irradiation — C.Y. Cho, J.-H. Kim, et al. · Edelweiss Applied Science and Technology (2024) | TGRS Research Map | TGRS