Single‐shot multi‐<i>b</i>‐value (SSMb) diffusion‐weighted MRI using spin echo and stimulated echoes with variable flip angles
Conventional diffusion-weighted imaging (DWI) sequences employing a spin echo or stimulated echo sensitize diffusion with a specific b-value at a fixed diffusion direction and diffusion time (Δ). To compute apparent diffusion coefficient (ADC) and other diffusion parameters, the sequence needs to be repeated multiple times by varying the b-value and/or gradient direction. In this study, we developed a single-shot multi-b-value (SSMb) diffusion MRI technique, which combines a spin echo and a train of stimulated echoes produced with variable flip angles. The method involves a pair of 90° radio frequency (RF) pulses that straddle a diffusion gradient lobe (G<sub>D</sub>), to rephase the magnetization in the transverse plane, producing a diffusion-weighted spin echo acquired by the first echo-planar imaging (EPI) readout train. The magnetization stored along the longitudinal axis is successively re-excited by a series of n variable-flip-angle pulses, each followed by a diffusion gradient lobe G<sub>D</sub> and a subsequent EPI readout train to sample n stimulated-echo signals. As such, (n + 1) diffusion-weighted images, each with a distinct b-value, are acquired in a single shot. The SSMb sequence was demonstrated on a diffusion phantom and healthy human brain to produce diffusion-weighted images, which were quantitative analyzed using a mono-exponential model. In the phantom experiment, SSMb provided similar ADC values to those from a commercial spin-echo EPI (SE-EPI) sequence (r = 0.999). In the human brain experiment, SSMb enabled a fourfold scan time reduction and yielded slightly lower ADC values (0.83 ± 0.26 μm<sup>2</sup>/ms) than SE-EPI (0.88 ± 0.29 μm<sup>2</sup>/ms) in all voxels excluding cerebrospinal fluid, likely due to the influence of varying diffusion times. The feasibility of using SSMb to acquire multiple images in a single shot for intravoxel incoherent motion (IVIM) analysis was also demonstrated. In conclusion, despite a relatively low signal-to-noise ratio, the proposed SSMb technique can substantially increase the data acquisition efficiency in DWI studies.
Authors
- Guangyu Dan (ORCID: https://orcid.org/0000-0003-0427-5661)
- Qingfei Luo (ORCID: https://orcid.org/0000-0002-1078-799X)
- Xiaohong Joe Zhou (ORCID: https://orcid.org/0000-0003-0793-4925)
- Kaibao Sun (ORCID: https://orcid.org/0000-0001-6923-5914)
Institutions
- Illinois College (US)
- University of Illinois Chicago (US)
- Resonance Research (United States) (US)
Publication Details
- Journal
- NMR in Biomedicine
- Published
- 2024-09-22
- DOI
- https://doi.org/10.1002/nbm.5261
- Citations
- 2
- Primary Topic
- Advanced Neuroimaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.81
Funders
- National Institutes of Health
- National Institute of Standards and Technology