Microwave Sensor for Sodium Chloride Density Measurement in Aqueous Solutions

Accurate determination of sodium chloride (NaCl) density in water is vital for assessing environmental impact, preventing soil salinization in agriculture, ensuring quality and consistency in industrial processes, facilitating medical treatments, and maintaining taste and preservation standards in the food and beverage industry. This paper introduces a novel microwave sensor design specifically tailored to accurately assess NaCl density in aqueous solutions. Starting with a standard solution of 10 g of salt dissolved in 100 ml of water, resulting in a molarity of approximately 1.71 M, five distinct samples are meticulously prepared. These samples cover a range of NaCl concentrations, with different ratios of salt solution and drinking water, including pure water, 10 ml of salt solution with 90 ml of water, 20 ml of salt solution with 80 ml of water, 30 ml of salt solution with 70 ml of water, and 40 ml of salt solution with 60 ml of water. Each sample undergoes analysis using the developed microwave sensor to determine its transmission coefficient. The magnitude of the transmission coefficient is closely tied to the density of the salt solution based on molarity. Through a detailed regression analysis, a strong quantitative relationship between the transmission coefficient and salt solution density is revealed. This correlation can be accurately represented by a third-order polynomial equation. This research is significant as it advances microwave sensor technology, allowing for accurate and efficient measurement of NaCl density in water.

Authors

Institutions

Publication Details

Journal
Journal of Engineering Technology and Applied Physics
Published
2024-09-15
DOI
https://doi.org/10.33093/jetap.2024.6.2.8
Citations
3
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microwave Sensor for Sodium Chloride Density Measurement in Aqueous Solutions

Kim Ho Yeap, Siu Hong Loh, Dakulagi Veerendra, Ahmad Uzair Mazlan et al.
3 citations
Journal of Engineering Technology and Applied Physics
Acoustic Wave Resonator Technologies
0.55
article

Microwave Sensor for Sodium Chloride Density Measurement in Aqueous Solutions

Kim Ho Yeap, Siu Hong Loh, Dakulagi Veerendra, Ahmad Uzair Mazlan, Jia Le Lam
article en
3 citations

Abstract

Accurate determination of sodium chloride (NaCl) density in water is vital for assessing environmental impact, preventing soil salinization in agriculture, ensuring quality and consistency in industrial processes, facilitating medical treatments, and maintaining taste and preservation standards in the food and beverage industry. This paper introduces a novel microwave sensor design specifically tailored to accurately assess NaCl density in aqueous solutions. Starting with a standard solution of 10 g of salt dissolved in 100 ml of water, resulting in a molarity of approximately 1.71 M, five distinct samples are meticulously prepared. These samples cover a range of NaCl concentrations, with different ratios of salt solution and drinking water, including pure water, 10 ml of salt solution with 90 ml of water, 20 ml of salt solution with 80 ml of water, 30 ml of salt solution with 70 ml of water, and 40 ml of salt solution with 60 ml of water. Each sample undergoes analysis using the developed microwave sensor to determine its transmission coefficient. The magnitude of the transmission coefficient is closely tied to the density of the salt solution based on molarity. Through a detailed regression analysis, a strong quantitative relationship between the transmission coefficient and salt solution density is revealed. This correlation can be accurately represented by a third-order polynomial equation. This research is significant as it advances microwave sensor technology, allowing for accurate and efficient measurement of NaCl density in water.

Journal of Engineering Technology and Applied PhysicsVol. 6(2)
Guru Nanak Dev University (IN), Universiti Tunku Abdul Rahman (MY)
Openalex Percentile: Top 37%
Acoustic Wave Resonator Technologies
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microwave Sensor for Sodium Chloride Density Measurement in Aqueous Solutions — Kim Ho Yeap, Siu Hong Loh, et al. · Journal of Engineering Technology and Applied Physics (2024) | TGRS Research Map | TGRS