Investigation of DG units influence on 66 kV sub-transmission system network considering region load growth: a case study

Abstract Voltage breakdown in sub-transmission networks resulting from an increase in load demand can be addressed by incorporating distributed generation (DG) units such as hydro, wind, photovoltaic, and geothermal in some buses. This approach can lower power losses and the price of the primary generated energy while increasing network dependability and efficiency. Feasibility of dispersed generation integration & its effect on sub-transmission system operation were investigated using Ben Walied 66 kV sub-transmission network in Libya as a state. This study presents modified particle swarm optimization (MOPSO) technique to select the best option with dispersed generation units under various operating conditions. The Ben Walied 66 kV sub-transmission network has been subject of effects research on both normal operation and load growth scenarios. The goal of this study was to find best way to adjust penetration level of the three DGs in response to changes in the network loading. Three DG units have been refitted to study the effects on test networks for sub-transmission, which consist of 30 and 51 buses. A comparison analysis shows that while the ideal locations of DG units remain constant with load expansion, the optimal solution for the penetration level percentage of three DG units was boosted by new optimal sizes. Research has been done on how the power factor of distributed generators (DGs) affects the practical performance of 66 kV networks in steady-state conditions. The integration of DG units in regulating these losses and voltage variations is demonstrated by the results, which indicate that the ideal solution for DG unit’s power factor was at a value of 0.87 lagging.

Authors

Institutions

Publication Details

Journal
International Journal of Emerging Electric Power Systems
Published
2024-09-23
DOI
https://doi.org/10.1515/ijeeps-2023-0166
Citations
1
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of DG units influence on 66 kV sub-transmission system network considering region load growth: a case study

Almoataz Y. Abdelaziz, Adel Salem Sultan, Papia Ray, Mahmoud A. Attia
1 citations
International Journal of Emerging Electric Power Systems
Optimal Power Flow Distribution
0.21
article

Investigation of DG units influence on 66 kV sub-transmission system network considering region load growth: a case study

Almoataz Y. Abdelaziz, Adel Salem Sultan, Papia Ray, Mahmoud A. Attia
article en
1 citations

Abstract

Abstract Voltage breakdown in sub-transmission networks resulting from an increase in load demand can be addressed by incorporating distributed generation (DG) units such as hydro, wind, photovoltaic, and geothermal in some buses. This approach can lower power losses and the price of the primary generated energy while increasing network dependability and efficiency. Feasibility of dispersed generation integration & its effect on sub-transmission system operation were investigated using Ben Walied 66 kV sub-transmission network in Libya as a state. This study presents modified particle swarm optimization (MOPSO) technique to select the best option with dispersed generation units under various operating conditions. The Ben Walied 66 kV sub-transmission network has been subject of effects research on both normal operation and load growth scenarios. The goal of this study was to find best way to adjust penetration level of the three DGs in response to changes in the network loading. Three DG units have been refitted to study the effects on test networks for sub-transmission, which consist of 30 and 51 buses. A comparison analysis shows that while the ideal locations of DG units remain constant with load expansion, the optimal solution for the penetration level percentage of three DG units was boosted by new optimal sizes. Research has been done on how the power factor of distributed generators (DGs) affects the practical performance of 66 kV networks in steady-state conditions. The integration of DG units in regulating these losses and voltage variations is demonstrated by the results, which indicate that the ideal solution for DG unit’s power factor was at a value of 0.87 lagging.

International Journal of Emerging Electric Power SystemsVol. 26(4)
Ain Shams University (EG), Veer Surendra Sai University of Technology (IN), Future University in Egypt (EG)
Openalex Percentile: Top 48%
Optimal Power Flow Distribution
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.