Development of a One Dollar Blood Pressure Monitor

BPClip is an ultra-low-cost cuffless blood pressure monitor. As a universal smartphone attachment, BPClip leverages the computational imaging power of smartphones to perform oscillometry based blood pressure measurements. This paper examines different design considerations in BPClip's development. The cost and accuracy of blood pressure measurements are the central design goals. Both requirements are achieved with the initial prototype that achieves a 0.80 USD material cost and a mean absolute error of 8.72 and 5.49 mmHg for systolic and diastolic blood pressure, respectively. Since a main motivator to develop BPClip is making blood pressure monitoring more accessible, usability is also central to the design. User studies were conducted throughout the design process to inform the most intuitive and accessible design features. In this paper, we demystify the design process to share effective design practices with future developers working towards expanding health monitoring access beyond traditional clinical settings.

Authors

Institutions

Publication Details

Published
2024-09-22
DOI
https://doi.org/10.1145/3675094.3677603
Primary Topic
Blood Pressure and Hypertension Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a One Dollar Blood Pressure Monitor

Yinan Xuan, Colin Barry, Edward Jay Wang, Ava J. Fascetti
Blood Pressure and Hypertension Studies
article

Development of a One Dollar Blood Pressure Monitor

Yinan Xuan, Colin Barry, Edward Jay Wang, Ava J. Fascetti
article en

Abstract

BPClip is an ultra-low-cost cuffless blood pressure monitor. As a universal smartphone attachment, BPClip leverages the computational imaging power of smartphones to perform oscillometry based blood pressure measurements. This paper examines different design considerations in BPClip's development. The cost and accuracy of blood pressure measurements are the central design goals. Both requirements are achieved with the initial prototype that achieves a 0.80 USD material cost and a mean absolute error of 8.72 and 5.49 mmHg for systolic and diastolic blood pressure, respectively. Since a main motivator to develop BPClip is making blood pressure monitoring more accessible, usability is also central to the design. User studies were conducted throughout the design process to inform the most intuitive and accessible design features. In this paper, we demystify the design process to share effective design practices with future developers working towards expanding health monitoring access beyond traditional clinical settings.

University of California San Diego (US)
Openalex Percentile: Top 71%
Blood Pressure and Hypertension Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a One Dollar Blood Pressure Monitor — Yinan Xuan, Colin Barry, et al. · (2024) | TGRS Research Map | TGRS