Experimental study on high temperature gaseous hydrogen fluoride corrosion of boiler water-cooled wall pipes
Hydrogen fluoride (HF) corrosion of boiler water-cooled wall pipes at high temperature hinders the co-disposal of fluorinated hazardous wastes and coal by combustion. In this paper, common water-cooled wall pipes (15CrMoG and 20G) were utilized to perform gaseous HF corrosion experiments at high temperature on a horizontal tube furnace. The effects of temperature on HF corrosion of different water-cooled wall pipes in 0.2% HF were investigated. Corrosion kinetics curve was obtained by calculating the mass increase due to corrosion. The microscopic morphology and physical phase composition of water-cooled wall pipes after HF corrosion were analyzed. The corrosion resistances of the two water-cooled wall pipes decrease with increasing the temperature. The corrosion weight gain curves of 15CrMoG and 20G at 550 ℃ are Δ<i>W</i><sup>1.9144 </sup>= 0.2100<i>t</i> and Δ<i>W</i><sup>1.8356 </sup>= 0.1344<i>t</i>, respectively. The average corrosion rates of 15CrMoG and 20G are 0.0177 and 0.0125 mg/(cm<sup>2</sup>·h), respectively. The corrosion resistance of 15CrMoG is superior compared to 20G. The HF corrosion at high temperature consists of non-alternating fluorination and oxidation of the metal matrix. This study is of great significance for the protection of boilers with HF corrosion at high temperature.
Authors
- Kuihua Han (ORCID: https://orcid.org/0000-0003-3337-0158)
- Lianqin Jia
- Jigang Zhang (ORCID: https://orcid.org/0000-0002-1850-5176)
- Kun Cheng (ORCID: https://orcid.org/0000-0002-1447-1845)
- Zijun Liu (ORCID: https://orcid.org/0000-0003-3928-0428)
Institutions
- Shandong University (CN)
- Shandong Institute of Commerce & Technology (CN)
Publication Details
- Journal
- Environmental Technology
- Published
- 2024-09-21
- DOI
- https://doi.org/10.1080/09593330.2024.2405945
- Citations
- 1
- Primary Topic
- Nuclear Materials and Properties
- Type
- article
- Field-Weighted Citation Impact
- 0.12