An electronic energy compensation method for flattening the energy response of SiPM-GGAG:Ce,B based gamma detector

The energy response of gross gamma dose rate monitors needs to be flat in order to prevent overestimation of dose at low gamma energies. In this paper, a discriminator threshold modulation based electronic energy compensation algorithm has been proposed for SiPM-scintillator based gamma detectors. Theoretical simulation studies were carried out in order to optimize the parameters of the periodic ramp voltage used for modulation of the discriminator threshold of a SiPM-GGAG:Ce,B based gamma dose rate monitor. A customized threshold modulation circuit and signal processing electronics were developed for this gamma detector. For experimentally optimizing the parameters, the energy response studies of the detector, with and without the discriminator threshold modulation, were carried out. With the optimized parameters for a periodic ramp threshold, the count rates for 241Am (60 keV) and 60Co (1173 and 1332 keV) were observed to be within ±30% of the count rate obtained for 137Cs (662 keV). Using the electronic energy compensation techniques presented in this paper, a flat energy response of the SiPM-scintillator gamma detector for the energy range of 60 keV to 1.5 MeV could be achieved.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-09-21
DOI
https://doi.org/10.1093/rpd/ncae196
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An electronic energy compensation method for flattening the energy response of SiPM-GGAG:Ce,B based gamma detector

Mohit Tyagi, Sunil Kumar Singh, Anita Topkar, Pratip Mitra et al.
Radiation Protection Dosimetry
Radiation Detection and Scintillator Technologies
article

An electronic energy compensation method for flattening the energy response of SiPM-GGAG:Ce,B based gamma detector

Mohit Tyagi, Sunil Kumar Singh, Anita Topkar, Pratip Mitra, Amit Kumar, A. Kumar, Saurabh Srivastava
article en

Abstract

The energy response of gross gamma dose rate monitors needs to be flat in order to prevent overestimation of dose at low gamma energies. In this paper, a discriminator threshold modulation based electronic energy compensation algorithm has been proposed for SiPM-scintillator based gamma detectors. Theoretical simulation studies were carried out in order to optimize the parameters of the periodic ramp voltage used for modulation of the discriminator threshold of a SiPM-GGAG:Ce,B based gamma dose rate monitor. A customized threshold modulation circuit and signal processing electronics were developed for this gamma detector. For experimentally optimizing the parameters, the energy response studies of the detector, with and without the discriminator threshold modulation, were carried out. With the optimized parameters for a periodic ramp threshold, the count rates for 241Am (60 keV) and 60Co (1173 and 1332 keV) were observed to be within ±30% of the count rate obtained for 137Cs (662 keV). Using the electronic energy compensation techniques presented in this paper, a flat energy response of the SiPM-scintillator gamma detector for the energy range of 60 keV to 1.5 MeV could be achieved.

Radiation Protection DosimetryVol. 200(19)
Bhabha Atomic Research Centre (IN), Homi Bhabha National Institute (IN)
Department of Atomic Energy, Government of India
Openalex Percentile: Top 79%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An electronic energy compensation method for flattening the energy response of SiPM-GGAG:Ce,B based gamma detector — Mohit Tyagi, Sunil Kumar Singh, et al. · Radiation Protection Dosimetry (2024) | TGRS Research Map | TGRS