Electrochemical impedance spectroscopy measurements on time-variant systems: the case of the Volmer-Heyrovský corrosion reaction. Part I: theoretical description

One of the theoretical requirements of electrochemical impedance spectroscopy measure-ments is that the studied system should not vary with time. Unfortunately, this is rarely the case of physical systems. In the literature, quite a few methods exist to check and correct a posteriori the effect of time-variance, allowing the use of conventional equivalent circuit models to fit and interpret the data. We suggest a different approach where, for a given electrochemical mechanism and specific experimental conditions, assuming stationarity during each measurement, a time- and frequency-dependent expression of the Faradaic impe¬dance is derived from the kinetic equations. The case of a potential relaxation at zero current following an anodic steady-state polarization is considered for a system where a Volmer-Heyrovský corrosion mechanism is supposed to take place.

Authors

Institutions

Publication Details

Journal
Journal of Electrochemical Science and Engineering
Published
2024-09-20
DOI
https://doi.org/10.5599/jese.2467
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical impedance spectroscopy measurements on time-variant systems: the case of the Volmer-Heyrovský corrosion reaction. Part I: theoretical description

Nicolas Murer, Bogdan Petrescu, Jean-Paul Diard
Journal of Electrochemical Science and Engineering
Corrosion Behavior and Inhibition
article

Electrochemical impedance spectroscopy measurements on time-variant systems: the case of the Volmer-Heyrovský corrosion reaction. Part I: theoretical description

Nicolas Murer, Bogdan Petrescu, Jean-Paul Diard
article en

Abstract

One of the theoretical requirements of electrochemical impedance spectroscopy measure-ments is that the studied system should not vary with time. Unfortunately, this is rarely the case of physical systems. In the literature, quite a few methods exist to check and correct a posteriori the effect of time-variance, allowing the use of conventional equivalent circuit models to fit and interpret the data. We suggest a different approach where, for a given electrochemical mechanism and specific experimental conditions, assuming stationarity during each measurement, a time- and frequency-dependent expression of the Faradaic impe¬dance is derived from the kinetic equations. The case of a potential relaxation at zero current following an anodic steady-state polarization is considered for a system where a Volmer-Heyrovský corrosion mechanism is supposed to take place.

Journal of Electrochemical Science and EngineeringVol. 15(1)
Sequans Communications (France) (FR)
Openalex Percentile: Top 90%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.