Flexible endoscope manipulating robot using quad-roller friction mechanism

A robotic system for manipulating a flexible endoscope in surgery can provide enhanced accuracy and usability compared to manual operation. However, previous studies require large-scale, complex hardware systems to implement the rotational and translational motions of the soft endoscope cable. The conventional control of the endoscope by actuating the endoscope handle also leads to undesired slack between the endoscope tip and the handle, which becomes more problematic with long endoscopes such as a colonoscope. This study proposes a compact quad-roller friction mechanism that enables rotational and translational motions triggered not from the endoscope handle but at the endoscope tip. Controlling two pairs of tilted rollers achieves both types of motion within a small space. The proposed system also introduces an unsynchronized motion strategy between the handle and tip parts to minimize the robot's motion near the patient by employing the slack positively as a control index. Experiments indicate that the proposed system achieves accurate rotational and translational motions, and the unsynchronized control method reduces the total translational motion by up to 88% compared to the previous method.

Authors

Institutions

Publication Details

Journal
Computer Assisted Surgery
Published
2024-09-21
DOI
https://doi.org/10.1080/24699322.2024.2404695
Citations
1
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible endoscope manipulating robot using quad-roller friction mechanism

Subin Lee, Hyeonwook Kim, Jaesung Hong, Hyun‐Joo Lee et al.
1 citations
Computer Assisted Surgery
Soft Robotics and Applications
0.18
article

Flexible endoscope manipulating robot using quad-roller friction mechanism

Subin Lee, Hyeonwook Kim, Jaesung Hong, Hyun‐Joo Lee, Seongbo Shim, Jaehyeon Byeon
article en
1 citations

Abstract

A robotic system for manipulating a flexible endoscope in surgery can provide enhanced accuracy and usability compared to manual operation. However, previous studies require large-scale, complex hardware systems to implement the rotational and translational motions of the soft endoscope cable. The conventional control of the endoscope by actuating the endoscope handle also leads to undesired slack between the endoscope tip and the handle, which becomes more problematic with long endoscopes such as a colonoscope. This study proposes a compact quad-roller friction mechanism that enables rotational and translational motions triggered not from the endoscope handle but at the endoscope tip. Controlling two pairs of tilted rollers achieves both types of motion within a small space. The proposed system also introduces an unsynchronized motion strategy between the handle and tip parts to minimize the robot's motion near the patient by employing the slack positively as a control index. Experiments indicate that the proposed system achieves accurate rotational and translational motions, and the unsynchronized control method reduces the total translational motion by up to 88% compared to the previous method.

Computer Assisted SurgeryVol. 29(1)
Daegu Gyeongbuk Institute of Science and Technology (KR), Kyungpook National University Hospital (KR), Korea Institute of Machinery & Materials (KR)
Affordable and clean energy
Openalex Percentile: Top 52%
Soft Robotics and Applications
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.