Bioanalytical method for the simultaneous estimation of atoltivimab, maftivimab and odesivimab in rat plasma by LCMS/MS and its application to a pharmacokinetic study

Background: A quick, accurate, reproducible, and straightforward liquid chromatography-tandem mass spectrometry(LC-MS/MS) system employing Atoltavimab, Maftivimab, and Odesivimab as an internal standard for Zanamivir quantification was achieved. Zanamivir is a neuraminidase inhibitor that effectively treats influenza caused by influenza A and B viruses. Methodology: Whenever we use the Kinetex C-18 column, all HPLC parameters and conditions are obeyed, so we use this column. Separation was performed on a Kinetex C18 column (100 mm x 4.6 mm, 2.6µm) using isocratic elution with a buffer containing 1mL of formic acid in 1Lit of water and a mobile step consisting of a 40:60 v/v mixture of two elements, buffer and acetonitrile, with a flow rate of 1mL/min at 300C temperature was used. Results & Discussion: We used different stationary phases in the optimization process, such as C18, C8, and CN-propyl. Using a kinetex C18 column with dimensions of (100 mm x 4.6 mm, 2.6 µm) connected to a PDA detector, we obtain strong peak shapes of Atoltivimab, Maftivimab, and Odesivimab from various trials. Flow rates in the mobile process were set to 1 mL/min. Conclusion: Atoltivimab, Maftivimab, and Odesivimab analysis was completed in 7 minutes over a good linear concentration range of 5ng/mL to 100ng/mL (r2 = 0.999), 5ng/mL to 100ng/mL (r2 = 0.999), and 5ng/mL to 100ng/mL (r2 = 0.9998). The findings of the precision and recovery studies are within the appropriate range.

Authors

Institutions

Publication Details

Journal
Journal of Applied Pharmaceutical Research
Published
2024-08-31
DOI
https://doi.org/10.69857/joapr.v12i4.607
Primary Topic
Biosimilars and Bioanalytical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bioanalytical method for the simultaneous estimation of atoltivimab, maftivimab and odesivimab in rat plasma by LCMS/MS and its application to a pharmacokinetic study

Ibrahim Baje Syed, Madhavi Nannapaneni
Journal of Applied Pharmaceutical Research
Biosimilars and Bioanalytical Methods
article

Bioanalytical method for the simultaneous estimation of atoltivimab, maftivimab and odesivimab in rat plasma by LCMS/MS and its application to a pharmacokinetic study

Ibrahim Baje Syed, Madhavi Nannapaneni
article en

Abstract

Background: A quick, accurate, reproducible, and straightforward liquid chromatography-tandem mass spectrometry(LC-MS/MS) system employing Atoltavimab, Maftivimab, and Odesivimab as an internal standard for Zanamivir quantification was achieved. Zanamivir is a neuraminidase inhibitor that effectively treats influenza caused by influenza A and B viruses. Methodology: Whenever we use the Kinetex C-18 column, all HPLC parameters and conditions are obeyed, so we use this column. Separation was performed on a Kinetex C18 column (100 mm x 4.6 mm, 2.6µm) using isocratic elution with a buffer containing 1mL of formic acid in 1Lit of water and a mobile step consisting of a 40:60 v/v mixture of two elements, buffer and acetonitrile, with a flow rate of 1mL/min at 300C temperature was used. Results & Discussion: We used different stationary phases in the optimization process, such as C18, C8, and CN-propyl. Using a kinetex C18 column with dimensions of (100 mm x 4.6 mm, 2.6 µm) connected to a PDA detector, we obtain strong peak shapes of Atoltivimab, Maftivimab, and Odesivimab from various trials. Flow rates in the mobile process were set to 1 mL/min. Conclusion: Atoltivimab, Maftivimab, and Odesivimab analysis was completed in 7 minutes over a good linear concentration range of 5ng/mL to 100ng/mL (r2 = 0.999), 5ng/mL to 100ng/mL (r2 = 0.999), and 5ng/mL to 100ng/mL (r2 = 0.9998). The findings of the precision and recovery studies are within the appropriate range.

Journal of Applied Pharmaceutical ResearchVol. 12(4)
GNA University (IN), Andhra Pradesh Forest Department (IN)
Openalex Percentile: Top 80%
Biosimilars and Bioanalytical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.