Powerful Electronic Systems for Conversion of Parameters of Electrical Energy with Nonlinear Pulse-Width Regulation of the Output Voltage

The modified method of the synchronous pulse-width regulation of inverters of variable-voltage variable-frequency electric drives makes it possible to provide control modes with the required nonlinear relationships between the magnitude of the output voltage of the inverter unit and the operating frequency of an ac drive. Thus modernized techniques and algorithms for the synchronous pulse-width regulation of inverter units of three-phase and six-phase variable-frequency electric drives ensure continuous synchronization and symmetry of the phase and line voltages in systems over the entire control range. In the spectra of the base voltages of the systems, there were no even harmonics and subharmonics (of operating frequency of drives), thereby helping to reduce losses in those installations and increase the efficiency of their operation.

Authors

Publication Details

Journal
Elektronnaya Obrabotka Materialov
Published
2024-09-01
DOI
https://doi.org/10.52577/eom.2024.60.4.67
Citations
1
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Powerful Electronic Systems for Conversion of Parameters of Electrical Energy with Nonlinear Pulse-Width Regulation of the Output Voltage

V. Oleschuk
1 citations
Elektronnaya Obrabotka Materialov
Electric Power Systems and Control
0.21
article

Powerful Electronic Systems for Conversion of Parameters of Electrical Energy with Nonlinear Pulse-Width Regulation of the Output Voltage

V. Oleschuk
article en
1 citations

Abstract

The modified method of the synchronous pulse-width regulation of inverters of variable-voltage variable-frequency electric drives makes it possible to provide control modes with the required nonlinear relationships between the magnitude of the output voltage of the inverter unit and the operating frequency of an ac drive. Thus modernized techniques and algorithms for the synchronous pulse-width regulation of inverter units of three-phase and six-phase variable-frequency electric drives ensure continuous synchronization and symmetry of the phase and line voltages in systems over the entire control range. In the spectra of the base voltages of the systems, there were no even harmonics and subharmonics (of operating frequency of drives), thereby helping to reduce losses in those installations and increase the efficiency of their operation.

Elektronnaya Obrabotka MaterialovVol. 60(4)
Affordable and clean energy
Openalex Percentile: Top 48%
Electric Power Systems and Control
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.