Optimizing cascade refrigeration systems with low GWP refrigerants for Low-Temperature Applications: A thermodynamic analysis

This study offers a comprehensive thermodynamic analysis of a cascade refrigeration system conducted for low-temperature applications, focusing on the use of low-GWP and zero-ODP refrigerants to improve efficiency and sustainability. The target of this study is to explore the performance of the system using a combination of refrigerants: low-temperature cycle refrigerants such as R744, while high-temperature cycle refrigerants such as R717, R1234yf, R1234ze(E), R1336mzz(E), and R1336mzz(Z), respectively. The ECS model incorporating in REFPROP 10.0a tool was utilized to extract the data through coding for analysis. The assessment of this system involves the examination of various parameters such as its coefficient of performance, total compressor workload, total exergy, and exergy efficiency across various operational conditions. The results are compared with and without superheated and subcooled conditions to understand the impact of these parameters on the system performance. The system with R744 in the low-temperature cycle and R717, R1234yf, R1234ze(E), R1336mzz(E), and R1336mzz(Z) in the high-temperature cycle provides a higher COP and lower total compressor work compared to the conventional cascade refrigeration system. In optimal CRS, the R744-R717 pair attains the highest COP of 2.05 at the lowest possible compressor work from 9.53 to 4.87 kW than other refrigerants pair while evaporator temperature shifting from −55 °C to −20 °C. The exergy efficiency of R744/R717 is found at 26.47 % at an evaporator temperature of −55 °C, but it extends to a peak of 51.73 % at −20 °C. The study also shows that the superheating and sub-cooling of the refrigerants have a significant impact on the performance of the cascade refrigeration system. Superheating and sub-cooling at 10 °C, improves the COP of the system by reducing the compressor work and increasing the heat transfer efficiency. The research offers valuable insights into the system’s thermodynamic performance when employing low GWP refrigerants in low-temperature applications. These findings have the potential to guide the design and optimization of cascade refrigeration systems over the range of low-temperature applications.

Authors

Publication Details

Journal
Energy Conversion and Management X
Published
2024-09-21
DOI
https://doi.org/10.1016/j.ecmx.2024.100722
Citations
6
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing cascade refrigeration systems with low GWP refrigerants for Low-Temperature Applications: A thermodynamic analysis

Md. Ashraful Islam, Dipayan Mondal, M. Arefin
6 citations
Energy Conversion and Management X
Refrigeration and Air Conditioning Technologies
1.28
article

Optimizing cascade refrigeration systems with low GWP refrigerants for Low-Temperature Applications: A thermodynamic analysis

Md. Ashraful Islam, Dipayan Mondal, M. Arefin
article en
6 citations

Abstract

This study offers a comprehensive thermodynamic analysis of a cascade refrigeration system conducted for low-temperature applications, focusing on the use of low-GWP and zero-ODP refrigerants to improve efficiency and sustainability. The target of this study is to explore the performance of the system using a combination of refrigerants: low-temperature cycle refrigerants such as R744, while high-temperature cycle refrigerants such as R717, R1234yf, R1234ze(E), R1336mzz(E), and R1336mzz(Z), respectively. The ECS model incorporating in REFPROP 10.0a tool was utilized to extract the data through coding for analysis. The assessment of this system involves the examination of various parameters such as its coefficient of performance, total compressor workload, total exergy, and exergy efficiency across various operational conditions. The results are compared with and without superheated and subcooled conditions to understand the impact of these parameters on the system performance. The system with R744 in the low-temperature cycle and R717, R1234yf, R1234ze(E), R1336mzz(E), and R1336mzz(Z) in the high-temperature cycle provides a higher COP and lower total compressor work compared to the conventional cascade refrigeration system. In optimal CRS, the R744-R717 pair attains the highest COP of 2.05 at the lowest possible compressor work from 9.53 to 4.87 kW than other refrigerants pair while evaporator temperature shifting from −55 °C to −20 °C. The exergy efficiency of R744/R717 is found at 26.47 % at an evaporator temperature of −55 °C, but it extends to a peak of 51.73 % at −20 °C. The study also shows that the superheating and sub-cooling of the refrigerants have a significant impact on the performance of the cascade refrigeration system. Superheating and sub-cooling at 10 °C, improves the COP of the system by reducing the compressor work and increasing the heat transfer efficiency. The research offers valuable insights into the system’s thermodynamic performance when employing low GWP refrigerants in low-temperature applications. These findings have the potential to guide the design and optimization of cascade refrigeration systems over the range of low-temperature applications.

Energy Conversion and Management XVol. 24
Affordable and clean energy
Openalex Percentile: Top 23%
Refrigeration and Air Conditioning Technologies
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.