Non-invasive ultrasonic sensing of internal conditions on a partial full-scale spent nuclear fuel canister mock-up
The safe storage of spent nuclear fuel (SNF) in dry cask storage systems (DCSSs) is critical to the nuclear fuel cycle and the future of nuclear energy. A critical component of DCSSs is the SNF canister. The canister is a sealed stainless-steel structure, which is first vacuum dried and then backfilled with helium. The structural deterioration within a canister can be monitored through its internal gas properties. This monitoring serves as the driving force behind the non-invasive ultrasonic sensing approach in this paper. A major challenge in collecting gas-borne signals using ultrasonic sensing is the impedance mismatch between the stainless-steel canister and the helium gas inside. Only a small fraction of the ultrasonic signal makes its way from the transmitter to the receiver through the gas medium. In this paper, experimental studies on a partial full-scale canister mock-up were carried out to capture the gas-borne signals. Damping materials were applied on the outside, and blocking and unblocking tests were conducted to identify the gas-borne signal. The research results showed that the excitation frequency played an important role in maximizing the gas-borne signals. The gas-borne signal was successfully detected at around the theoretical time-of-flight (TOF) at 225 kHz. A high signal-to-noise ratio (SNR) was achieved in the measurements. Next, acoustic impedance matching (AIM) layers were added, and it was found that the gas signal energy was improved by 160.4% compared with that of no AIM layers. Subsequently, the relative humidity (RH) level and temperature of the gas were varied to simulate abnormal internal conditions of the canister. The non-invasive testing system demonstrated reliability and sensitivity in detecting gas temperature and RH variations. Theoretical calculations demonstrated the potential for detecting low-level xenon and air within an actual SNF canister filled with helium. Last, an active noise cancellation (ANC) method, previously developed by the authors, was verified on the canister mock-up for the first time. The results showed that the SNR of the gas signal was improved by 213.6% compared with that of no ANC.
Authors
- Ryan M. Meyer (ORCID: https://orcid.org/0000-0002-6034-4556)
- Assad A. Oberai (ORCID: https://orcid.org/0000-0002-7668-7713)
- Bozhou Zhuang (ORCID: https://orcid.org/0000-0003-2123-8862)
- Anton Sinkov
- Bora Gencturk (ORCID: https://orcid.org/0000-0001-6920-0834)
- Morris S. Good
Institutions
- University of Southern California (US)
- Oak Ridge National Laboratory (US)
- Battelle (US)
- Pacific Northwest National Laboratory (US)
Publication Details
- Journal
- NDT & E International
- Published
- 2024-09-21
- DOI
- https://doi.org/10.1016/j.ndteint.2024.103242
- Citations
- 10
- Primary Topic
- Nuclear Engineering Thermal-Hydraulics
- Type
- article
- Field-Weighted Citation Impact
- 12.99
Funders
- U.S. Department of Energy
- Nuclear Energy University Program