Storage properties of platelet concentrates from umbilical cord blood prepared using three different methods
CBPCs were of comparable quality to control PCs during storage. However, apoptosis markers in both groups were elevated, suggesting processing and storage of low volumes of PCs require further optimization. Also, filtration of low volumes leads to significant platelet loss, an issue that requires remedy.