Development and validation of a highly sensitive UPLC–MS/MS method for the determination of Huperzine A in rat plasma

Huperzine A is a reversible and selective cholinesterase inhibitor and has been approved for the treatment of Alzheimer's diseases. In this study, we developed a highly sensitive and specific ulta-high-performance liquid chromatography-tandem mass spectrometry method for the determination of Huperzine A in rat plasma. An aliquot of 50 μL of rat plasma sample was pretreated with 200 μL of acetonitrile-methanol (v/v; 1:1) containing 0.2% formic acid followed by solid phase extraction. The resulting sample was separated on a Waters ACQUITY BEH C<sub>18</sub> column using acetonitrile and water containing 0.2% formic acid as mobile phase, at a flow rate of 0.3 mL/min. Multiple-reaction monitoring (MRM) mode was used for quantitative analysis of Huperzine A in positive electrospray ionization. In the concentration range of 0.01-10 ng/mL, Huperzine A showed excellent linearity with correlation coefficient > 0.998. The intra- and inter-day RSD% were less than 9.7%, while the RE% ranged from -6.7% to 10.0%. The mean recovery was >84.5%. The validated method was demonstrated to be selective, sensitive, and reliable, which has been successfully applied to pharmacokinetic study of Huperzine A in rat plasma. Huperzine A displayed a long half-life in rat plasma and high oral bioavailability.

Authors

Publication Details

Journal
Biomedical Chromatography
Published
2024-09-19
DOI
https://doi.org/10.1002/bmc.6011
Citations
1
Primary Topic
Cholinesterase and Neurodegenerative Diseases
Type
article
Field-Weighted Citation Impact
0.45
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of a highly sensitive UPLC–MS/MS method for the determination of Huperzine A in rat plasma

Haizhou Wang, Kejun Zhang
1 citations
Biomedical Chromatography
Cholinesterase and Neurodegenerative Diseases
0.45
article

Development and validation of a highly sensitive UPLC–MS/MS method for the determination of Huperzine A in rat plasma

Haizhou Wang, Kejun Zhang
article en
1 citations

Abstract

Huperzine A is a reversible and selective cholinesterase inhibitor and has been approved for the treatment of Alzheimer's diseases. In this study, we developed a highly sensitive and specific ulta-high-performance liquid chromatography-tandem mass spectrometry method for the determination of Huperzine A in rat plasma. An aliquot of 50 μL of rat plasma sample was pretreated with 200 μL of acetonitrile-methanol (v/v; 1:1) containing 0.2% formic acid followed by solid phase extraction. The resulting sample was separated on a Waters ACQUITY BEH C<sub>18</sub> column using acetonitrile and water containing 0.2% formic acid as mobile phase, at a flow rate of 0.3 mL/min. Multiple-reaction monitoring (MRM) mode was used for quantitative analysis of Huperzine A in positive electrospray ionization. In the concentration range of 0.01-10 ng/mL, Huperzine A showed excellent linearity with correlation coefficient > 0.998. The intra- and inter-day RSD% were less than 9.7%, while the RE% ranged from -6.7% to 10.0%. The mean recovery was >84.5%. The validated method was demonstrated to be selective, sensitive, and reliable, which has been successfully applied to pharmacokinetic study of Huperzine A in rat plasma. Huperzine A displayed a long half-life in rat plasma and high oral bioavailability.

Biomedical ChromatographyVol. 38(11)
Clean water and sanitation
Openalex Percentile: Top 31%
Cholinesterase and Neurodegenerative Diseases
0.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and validation of a highly sensitive UPLC–MS/MS method for the determination of Huperzine A in rat plasma — Haizhou Wang, Kejun Zhang · Biomedical Chromatography (2024) | TGRS Research Map | TGRS