Influence of increasing Integration of Solar photovoltaic on Small Signal and Transient stability of Nigeria Power System

Abstract In this paper, the effect of Solar Photovoltaic (SPV) penetration on the damping of critical and inter area modes arising from different penetration level of SPV into the Nigeria national grid has been studied. Also, the possible effects of SPV penetration on Critical Clearing Time (CCT) when a three-phase fault occurs on the grid are studied. The Nigeria 56-bus system was used for the investigation. Sensitivity analyses are carried out to obtain insight into how certain change in parameters affects both the transient and small signal stabilities of the Nigerian power systems. DigSILENT Power Factory was used for the simulation while the analysis was performed in MATLAB. Some of the important findings show that the grid developed increasing amplitude of oscillation from 20 % SPV penetration. There is no steady increase or decrease of CCT with penetration levels. The effect of changes in load on small signal conducted shows that both the real and imaginary load at Kano and Birnin kebbi bus should not exceed 257 MW, 176 MVAR and 171 MW, 134 MVAR, respectively so as to avoid system collapse.

Authors

Institutions

Publication Details

Journal
International Journal of Emerging Electric Power Systems
Published
2024-09-20
DOI
https://doi.org/10.1515/ijeeps-2024-0130
Citations
2
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of increasing Integration of Solar photovoltaic on Small Signal and Transient stability of Nigeria Power System

Adedayo A. Yusuff, Thapelo Mosetlhe, T.R. Ayodele, Richard O. Olarewaju et al.
2 citations
International Journal of Emerging Electric Power Systems
Power System Optimization and Stability
0.42
article

Influence of increasing Integration of Solar photovoltaic on Small Signal and Transient stability of Nigeria Power System

Adedayo A. Yusuff, Thapelo Mosetlhe, T.R. Ayodele, Richard O. Olarewaju, A.S.O. Ogunjuyigbe
article en
2 citations

Abstract

Abstract In this paper, the effect of Solar Photovoltaic (SPV) penetration on the damping of critical and inter area modes arising from different penetration level of SPV into the Nigeria national grid has been studied. Also, the possible effects of SPV penetration on Critical Clearing Time (CCT) when a three-phase fault occurs on the grid are studied. The Nigeria 56-bus system was used for the investigation. Sensitivity analyses are carried out to obtain insight into how certain change in parameters affects both the transient and small signal stabilities of the Nigerian power systems. DigSILENT Power Factory was used for the simulation while the analysis was performed in MATLAB. Some of the important findings show that the grid developed increasing amplitude of oscillation from 20 % SPV penetration. There is no steady increase or decrease of CCT with penetration levels. The effect of changes in load on small signal conducted shows that both the real and imaginary load at Kano and Birnin kebbi bus should not exceed 257 MW, 176 MVAR and 171 MW, 134 MVAR, respectively so as to avoid system collapse.

International Journal of Emerging Electric Power SystemsVol. 26(4)
University of South Africa (ZA), University of Ibadan (NG)
Openalex Percentile: Top 38%
Power System Optimization and Stability
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.