Adaptation of a Differential Scanning Calorimeter for Simultaneous Electromagnetic Measurements

Although much information can be gained about thermally induced microstructural changes in metals through the measurement of their thermophysical properties using a differential scanning calorimeter (DSC), due to competing influences on the signal, not all microstructural changes can be fully characterised this way. For example, accurate characterisation of recrystallisation, tempering, and changes in retained delta ferrite in alloyed steels becomes complex due to additional signal changes due to the Curie point, oxidation, and the rate (and therefore the magnitude) of transformation. However, these types of microstructural changes have been shown to invoke strong magnetic and electromagnetic (EM) responses; therefore, simultaneous EM measurements can provide additional complementary data which can help to emphasise or deconvolute these complex signals and develop a more complete understanding of certain metallurgical phenomena. This paper discusses how a DSC machine has been modified to incorporate an EM sensor consisting of two copper coils printed onto either side of a ceramic substrate, with one coil acting as a transmitter and the other as a receiver. The coil is interfaced with a custom-built data acquisition system, which provides current to the transmit coil, records signals from the receive coil, and is controlled by a graphical user interface which allows the user to select multiple excitation frequencies. The equipment has a useable frequency range of approximately 1-100 kHz and outputs phase and magnitude readings at a rate of approximately 50 samples per second. Simultaneous DSC-EM measurements were performed on a nickel sample up to a temperature of 600 °C, with the reversable ferromagnetic to paramagnetic transition in the nickel sample invoking a clear EM response. The results show that the combined DSC-EM apparatus has the potential to provide a powerful tool for the analysis of thermally induced microstructural changes in metals, feeding into research on steel production, development of magnetic and conductive materials, and many more areas.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-09-20
DOI
https://doi.org/10.3390/s24186077
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptation of a Differential Scanning Calorimeter for Simultaneous Electromagnetic Measurements

Anthony Peyton, Adam Fletcher, Claire Davis, Mohsen Aghadavoudi Jolfaei et al.
Sensors
Microwave and Dielectric Measurement Techniques
article

Adaptation of a Differential Scanning Calorimeter for Simultaneous Electromagnetic Measurements

Anthony Peyton, Adam Fletcher, Claire Davis, Mohsen Aghadavoudi Jolfaei, Carl Slater, John Wilson
article en

Abstract

Although much information can be gained about thermally induced microstructural changes in metals through the measurement of their thermophysical properties using a differential scanning calorimeter (DSC), due to competing influences on the signal, not all microstructural changes can be fully characterised this way. For example, accurate characterisation of recrystallisation, tempering, and changes in retained delta ferrite in alloyed steels becomes complex due to additional signal changes due to the Curie point, oxidation, and the rate (and therefore the magnitude) of transformation. However, these types of microstructural changes have been shown to invoke strong magnetic and electromagnetic (EM) responses; therefore, simultaneous EM measurements can provide additional complementary data which can help to emphasise or deconvolute these complex signals and develop a more complete understanding of certain metallurgical phenomena. This paper discusses how a DSC machine has been modified to incorporate an EM sensor consisting of two copper coils printed onto either side of a ceramic substrate, with one coil acting as a transmitter and the other as a receiver. The coil is interfaced with a custom-built data acquisition system, which provides current to the transmit coil, records signals from the receive coil, and is controlled by a graphical user interface which allows the user to select multiple excitation frequencies. The equipment has a useable frequency range of approximately 1-100 kHz and outputs phase and magnitude readings at a rate of approximately 50 samples per second. Simultaneous DSC-EM measurements were performed on a nickel sample up to a temperature of 600 °C, with the reversable ferromagnetic to paramagnetic transition in the nickel sample invoking a clear EM response. The results show that the combined DSC-EM apparatus has the potential to provide a powerful tool for the analysis of thermally induced microstructural changes in metals, feeding into research on steel production, development of magnetic and conductive materials, and many more areas.

SensorsVol. 24(18)
University of Manchester (GB), University of Warwick (GB)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 87%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.