Enhanced Water Resistance of TiO2–GO–SMS-Modified Soil Composite for Use as a Repair Material in Earthen Sites

Most earthen sites are located in open environments eroded by wind and rain, resulting in spalling and cracking caused by shrinkage due to constant water absorption and loss. Together, these issues seriously affect the stability of such sites. Gypsum-lime-modified soil offers relatively strong mechanical properties but poor water resistance. If such soil becomes damp or immersed in water, its strength is significantly reduced, making it unviable for use as a material in the preparation of earthen sites. In this study, we achieved the composite addition of a certain amount of sodium methyl silicate (SMS), titanium dioxide (TiO<sub>2</sub>), and graphene oxide (GO) into gypsum-lime-modified soil and analyzed the microstructural evolution of the composite-modified soil using characterization methods such as XRD, SEM, and EDS. A comparative study was conducted on changes in the mechanical properties of the composite-modified soil and original soil before and after immersion using water erosion, unconfined compression (UCS), and unconsolidated undrained (UU) triaxial compression tests. These analyses revealed the micro-mechanisms for improving the waterproof performance of the composite-modified soil. The results showed that the addition of SMS, TiO<sub>2</sub>, and GO did not change the crystal structure or composition of the original soil. In addition, TiO<sub>2</sub> and GO were evenly distributed between the modified soil particles, playing a positive role in filling and stabilizing the structure of the modified soil. After being immersed in water for one hour, the original soil experienced structural instability leading to collapse. While the water absorption rate of the composite-modified soil was only 0.84%, its unconfined compressive strength was 4.88 MPa (the strength retention rate before and after immersion was as high as 93.1%), and the shear strength was 614 kPa (the strength retention rate before and after immersion was as high as 96.7%).

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-09-20
DOI
https://doi.org/10.3390/ma17184610
Primary Topic
Microbial Applications in Construction Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Water Resistance of TiO2–GO–SMS-Modified Soil Composite for Use as a Repair Material in Earthen Sites

Zhiqiang Huang, Bao Wenbo, Yuxuan Guo, Yike Li et al.
Materials
Microbial Applications in Construction Materials
article

Enhanced Water Resistance of TiO2–GO–SMS-Modified Soil Composite for Use as a Repair Material in Earthen Sites

Zhiqiang Huang, Bao Wenbo, Yuxuan Guo, Yike Li, Ming Wang, Wei Li
article en

Abstract

Most earthen sites are located in open environments eroded by wind and rain, resulting in spalling and cracking caused by shrinkage due to constant water absorption and loss. Together, these issues seriously affect the stability of such sites. Gypsum-lime-modified soil offers relatively strong mechanical properties but poor water resistance. If such soil becomes damp or immersed in water, its strength is significantly reduced, making it unviable for use as a material in the preparation of earthen sites. In this study, we achieved the composite addition of a certain amount of sodium methyl silicate (SMS), titanium dioxide (TiO<sub>2</sub>), and graphene oxide (GO) into gypsum-lime-modified soil and analyzed the microstructural evolution of the composite-modified soil using characterization methods such as XRD, SEM, and EDS. A comparative study was conducted on changes in the mechanical properties of the composite-modified soil and original soil before and after immersion using water erosion, unconfined compression (UCS), and unconsolidated undrained (UU) triaxial compression tests. These analyses revealed the micro-mechanisms for improving the waterproof performance of the composite-modified soil. The results showed that the addition of SMS, TiO<sub>2</sub>, and GO did not change the crystal structure or composition of the original soil. In addition, TiO<sub>2</sub> and GO were evenly distributed between the modified soil particles, playing a positive role in filling and stabilizing the structure of the modified soil. After being immersed in water for one hour, the original soil experienced structural instability leading to collapse. While the water absorption rate of the composite-modified soil was only 0.84%, its unconfined compressive strength was 4.88 MPa (the strength retention rate before and after immersion was as high as 93.1%), and the shear strength was 614 kPa (the strength retention rate before and after immersion was as high as 96.7%).

MaterialsVol. 17(18)
Shenyang University of Technology (CN), Liaoning Technical University (CN)
Clean water and sanitation
Openalex Percentile: Top 86%
Microbial Applications in Construction Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.