Validation of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Determination of Selected Toxic Metals in the Decontamination Process of Wastewater Discharged in Natural Receivers

A new method based on high-resolution continuum source flame atomic absorption spectrometry (HR-CS-FAAS) was validated for the determination of selected toxic and potentially toxic metals in wastewater resulting from mining activity. The results were compared with inductively coupled plasma optical emission spectrometry (ICP-OES). The HR-CS-FAAS method was characterized by detection limits in the range (µg L-1) 0.9(Mn)-33.6(Pb), better than ICP-OES for Cu, Fe, Ni, Co, Pb and Mn, and poorer for Cd, Zn and Cr. The Dunnett's and Tukey's statistical test showed that both methods were not affected by significant bias against certified value and between them. The recovery in HR-CS-FAAS method was in the range of 98-103% with relative extended uncertainty of 9-25%, and precision of 1.5-14.1%. The results indicated that the HR-CS-FAAS method is suitable for the determination of toxic and potentially toxic elements directly in filtered water samples without any chemical treatment.

Authors

Institutions

Publication Details

Journal
Acta chimica slovenica
Published
2024-09-20
DOI
https://doi.org/10.17344/acsi.2023.8534
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Determination of Selected Toxic Metals in the Decontamination Process of Wastewater Discharged in Natural Receivers

Simion Bogdan Angyus, Tiberiu Frenţiu, Veronica Obuseng, Enikő Covaci et al.
Acta chimica slovenica
Analytical chemistry methods development
article

Validation of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Determination of Selected Toxic Metals in the Decontamination Process of Wastewater Discharged in Natural Receivers

Simion Bogdan Angyus, Tiberiu Frenţiu, Veronica Obuseng, Enikő Covaci, Bame Sanah Senna, Wellington Masamba
article en

Abstract

A new method based on high-resolution continuum source flame atomic absorption spectrometry (HR-CS-FAAS) was validated for the determination of selected toxic and potentially toxic metals in wastewater resulting from mining activity. The results were compared with inductively coupled plasma optical emission spectrometry (ICP-OES). The HR-CS-FAAS method was characterized by detection limits in the range (µg L-1) 0.9(Mn)-33.6(Pb), better than ICP-OES for Cu, Fe, Ni, Co, Pb and Mn, and poorer for Cd, Zn and Cr. The Dunnett's and Tukey's statistical test showed that both methods were not affected by significant bias against certified value and between them. The recovery in HR-CS-FAAS method was in the range of 98-103% with relative extended uncertainty of 9-25%, and precision of 1.5-14.1%. The results indicated that the HR-CS-FAAS method is suitable for the determination of toxic and potentially toxic elements directly in filtered water samples without any chemical treatment.

Acta chimica slovenicaVol. 71(3)
University of Botswana (BW), Botswana International University of Science and Technology (BW), Babeș-Bolyai University (RO), Research Institute for Analytical Instrumentation (RO)
Botswana International University of Science and Technology, European Commission, Ministerul Cercetării şi Inovării, Erasmus+
Clean water and sanitation
Openalex Percentile: Top 86%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.