Dynamic Failure Mode Analysis for a Transmission Tower-Line System Induced by Strong Winds

The prevailing approach to the wind resistance design of transmission towers is rooted in the quasi-static method. However, this methodology faces criticism for neglecting tower-line coupling dynamics. Despite efforts to boost structural wind resilience, the research on tower failure mechanisms, especially under extreme winds considering tower-line coupling, is limited. To address this gap, the wind-induced dynamic failure modes of the transmission tower-line system are investigated in this paper. The consistent discrete random flow generation method is employed to simulate the fluctuating wind field for transmission lines. Incorporating the compressive buckling mode of angle steel, the plastic hinge model of the frame element is employed to simulate mechanical nonlinearity. A typical transmission tower-line system is concerned, with a finite element model established for a three-tower, four-line coupled configuration. The findings reveal that the wind-induced collapse of the transmission tower is directly triggered by the buckling failure of the compressed main members, with the vulnerable section located beneath the lower cross-arm. The transmission tower experiences bidirectional bending and compression instability under an unfavorable wind direction. In contrast, the traditional pushover collapse modes of the transmission tower cannot fully capture the characteristics of the collapse failure, mainly due to the ignorance of the transverse wind force action induced by the coupling effect. This research underscores the importance of incorporating lateral dynamic considerations into transmission tower designs and advocates for optimizing strategies to mitigate wind-induced collapse modes.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-09-20
DOI
https://doi.org/10.3390/en17184679
Citations
8
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
2.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Failure Mode Analysis for a Transmission Tower-Line System Induced by Strong Winds

Shicheng Yan, Shizeng Liu, Lixiao Li, Chao Li et al.
8 citations
Energies
Vibration and Dynamic Analysis
2.63
article

Dynamic Failure Mode Analysis for a Transmission Tower-Line System Induced by Strong Winds

Shicheng Yan, Shizeng Liu, Lixiao Li, Chao Li, Qiang Li, Shihong Zhang, Wentong Zhang
article en
8 citations

Abstract

The prevailing approach to the wind resistance design of transmission towers is rooted in the quasi-static method. However, this methodology faces criticism for neglecting tower-line coupling dynamics. Despite efforts to boost structural wind resilience, the research on tower failure mechanisms, especially under extreme winds considering tower-line coupling, is limited. To address this gap, the wind-induced dynamic failure modes of the transmission tower-line system are investigated in this paper. The consistent discrete random flow generation method is employed to simulate the fluctuating wind field for transmission lines. Incorporating the compressive buckling mode of angle steel, the plastic hinge model of the frame element is employed to simulate mechanical nonlinearity. A typical transmission tower-line system is concerned, with a finite element model established for a three-tower, four-line coupled configuration. The findings reveal that the wind-induced collapse of the transmission tower is directly triggered by the buckling failure of the compressed main members, with the vulnerable section located beneath the lower cross-arm. The transmission tower experiences bidirectional bending and compression instability under an unfavorable wind direction. In contrast, the traditional pushover collapse modes of the transmission tower cannot fully capture the characteristics of the collapse failure, mainly due to the ignorance of the transverse wind force action induced by the coupling effect. This research underscores the importance of incorporating lateral dynamic considerations into transmission tower designs and advocates for optimizing strategies to mitigate wind-induced collapse modes.

EnergiesVol. 17(18)
Shenzhen University (CN), Harbin Institute of Technology (CN), Dongguan University of Technology (CN), China Southern Power Grid (China) (CN)
National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 10%
Vibration and Dynamic Analysis
2.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.