Use of Neutral Overvoltage Relay for Protection of Industrial Systems with DYN Transformer Operation in Intentional Island

This article briefly reviews the importance of distributed photovoltaic generation systems in industry and heir growing trend. It also addresses the problem of islanding in such systems and proposes an alternative for protecting power systems in the event of phase-to-ground faults in the ungrounded feeder during islanding using the neutral overvoltage relay. The 59N function of the relay eliminates the need for grounding transformers and prevents the power system from injecting phase-to-ground faults. This avoids potential catastrophic damage to equipment and personnel in the plant, as well as possible loss of profit. The study suggests that the use of the 59N function is a simple and cost- effective solution for photovoltaic generator ground-fault protection that provides greater safety during islanding operations.

Institutions

Publication Details

Journal
Anais Congresso Brasileiro de Energia Solar
Published
2024-09-20
DOI
https://doi.org/10.59627/cbens.2024.2370
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of Neutral Overvoltage Relay for Protection of Industrial Systems with DYN Transformer Operation in Intentional Island

Anais Congresso Brasileiro de Energia Solar
Electric Power Systems and Control
article

Use of Neutral Overvoltage Relay for Protection of Industrial Systems with DYN Transformer Operation in Intentional Island

article en

Abstract

This article briefly reviews the importance of distributed photovoltaic generation systems in industry and heir growing trend. It also addresses the problem of islanding in such systems and proposes an alternative for protecting power systems in the event of phase-to-ground faults in the ungrounded feeder during islanding using the neutral overvoltage relay. The 59N function of the relay eliminates the need for grounding transformers and prevents the power system from injecting phase-to-ground faults. This avoids potential catastrophic damage to equipment and personnel in the plant, as well as possible loss of profit. The study suggests that the use of the 59N function is a simple and cost- effective solution for photovoltaic generator ground-fault protection that provides greater safety during islanding operations.

Anais Congresso Brasileiro de Energia Solar
Universidade Federal do Espírito Santo (BR)
Openalex Percentile: Top 87%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.