Use of a confocal optical device for centring a diamond anvil cell in single-crystal X-ray diffraction experiments

High-pressure crystallographic data can be measured using a diamond anvil cell (DAC), which allows the sample to be viewed only along a cell vector which runs perpendicular to the diamond anvils. Although centring a sample perpendicular to this direction is straightforward, methods for centring along this direction often rely on sample focusing, measurements of the direct beam or short data collections followed by refinement of the crystal offsets. These methods may be inaccurate, difficult to apply or slow. Described here is a method based on precise measurement of the offset in this direction using a confocal optical device, whereby the cell centre is located at the mid-point of two measurements of the distance between a light source and the external faces of the diamond anvils viewed along the forward and reverse directions of the cell vector. It is shown that the method enables a DAC to be centred to within a few micrometres reproducibly and quickly.

Authors

Institutions

Publication Details

Journal
Journal of Applied Crystallography
Published
2024-09-20
DOI
https://doi.org/10.1107/s1600576724007829
Primary Topic
High-pressure geophysics and materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of a confocal optical device for centring a diamond anvil cell in single-crystal X-ray diffraction experiments

Simon Parsons, Cameron J. G. Wilson, Daniel M Scully, Tobias Stuerzer et al.
1 links
Journal of Applied Crystallography
High-pressure geophysics and materials
article

Use of a confocal optical device for centring a diamond anvil cell in single-crystal X-ray diffraction experiments

Simon Parsons, Cameron J. G. Wilson, Daniel M Scully, Tobias Stuerzer, Chengdao Hu
article en

Abstract

High-pressure crystallographic data can be measured using a diamond anvil cell (DAC), which allows the sample to be viewed only along a cell vector which runs perpendicular to the diamond anvils. Although centring a sample perpendicular to this direction is straightforward, methods for centring along this direction often rely on sample focusing, measurements of the direct beam or short data collections followed by refinement of the crystal offsets. These methods may be inaccurate, difficult to apply or slow. Described here is a method based on precise measurement of the offset in this direction using a confocal optical device, whereby the cell centre is located at the mid-point of two measurements of the distance between a light source and the external faces of the diamond anvils viewed along the forward and reverse directions of the cell vector. It is shown that the method enables a DAC to be centred to within a few micrometres reproducibly and quickly.

Journal of Applied CrystallographyVol. 57(5)
Shoreline Community College (US), Bruker (Germany) (DE), University of Edinburgh (GB)
University of Edinburgh, Engineering and Physical Sciences Research Council
Openalex Percentile: Top 83%
High-pressure geophysics and materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.