Using of Cotton Fabric and Fiber as Objects of Retrospective EPR Dosimetry

Purpose: Testing samples of cotton materials for their use as objects of recovery of accumulated dose by EPR dosimetry. Material and methods: Samples of cotton fabric and fabrics of mixed composition – lab coats, casual clothing items – shirts and jeans, as well as protective masks and respirators were irradiated using a linear electron accelerator model UELR-10-10C2 in the dose range from several Gy to 16 kGy. EPR spectra were recorded using the Bruker Elexsys-II E580 X-band EPR spectrometer with a SuperHighQ cylindrical resonator. Results: It was found that ionizing radiation induces free radicals in materials with triplet EPR signal, the most intense line of which has g = 2.019 and a linewidth 6 G. There was no or negligible native signal in uncolored fabrics. The radiation-induced EPR signal decayed exponentially with average half-life time of 62 hours. Conclusion: Clothing materials based on cotton fabrics, as well as materials of protective medical masks, have shown themselves suitable for use as an object of retrospective EPR dosimetry.

Authors

Publication Details

Journal
Medical Radiology and radiation safety
Published
2024-09-01
DOI
https://doi.org/10.33266/1024-6177-2024-69-5-109-113
Primary Topic
Radiation Effects and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using of Cotton Fabric and Fiber as Objects of Retrospective EPR Dosimetry

S. F. Konev, D. Baytimirov, E. E. Aladova, D.V. Ivanov
Medical Radiology and radiation safety
Radiation Effects and Dosimetry
article

Using of Cotton Fabric and Fiber as Objects of Retrospective EPR Dosimetry

S. F. Konev, D. Baytimirov, E. E. Aladova, D.V. Ivanov
article en

Abstract

Purpose: Testing samples of cotton materials for their use as objects of recovery of accumulated dose by EPR dosimetry. Material and methods: Samples of cotton fabric and fabrics of mixed composition – lab coats, casual clothing items – shirts and jeans, as well as protective masks and respirators were irradiated using a linear electron accelerator model UELR-10-10C2 in the dose range from several Gy to 16 kGy. EPR spectra were recorded using the Bruker Elexsys-II E580 X-band EPR spectrometer with a SuperHighQ cylindrical resonator. Results: It was found that ionizing radiation induces free radicals in materials with triplet EPR signal, the most intense line of which has g = 2.019 and a linewidth 6 G. There was no or negligible native signal in uncolored fabrics. The radiation-induced EPR signal decayed exponentially with average half-life time of 62 hours. Conclusion: Clothing materials based on cotton fabrics, as well as materials of protective medical masks, have shown themselves suitable for use as an object of retrospective EPR dosimetry.

Medical Radiology and radiation safetyVol. 69(5)
Openalex Percentile: Top 81%
Radiation Effects and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.