Frequency regulation of PV-reheat thermal power system via a novel hybrid educational competition optimizer with pattern search and cascaded PDN-PI controller

Maintaining a stable balance between generated power and load demand is a critical challenge in modern power systems, especially with the increasing integration of renewable energy sources like photovoltaic (PV) systems. This study introduces a novel hybrid educational competition optimizer with pattern search (hECO-PS) algorithm to optimally tune a cascaded proportional-derivative with filter and proportional-integral (PDN-PI) controller for load frequency control (LFC) in a two-area power system comprising a PV system and a reheat thermal power system. The proposed hECO-PS algorithm enhances both global exploration and local exploitation capabilities, resulting in superior convergence rates and solution accuracy. The controller's performance was evaluated under various scenarios, including a 10 % step load change and solar radiation variations, demonstrating significant improvements in frequency regulation. The hECO-PS tuned PDN-PI controller achieved a minimum integral of time-weighted absolute error (ITAE) value of 0.4464, outperforming conventional methods like the modified whale optimization algorithm and sea horse algorithm, which yielded ITAE values of 2.6198 and 0.8598, respectively. Furthermore, the proposed controller reduced settling time by up to 46 % and minimized overshoot by up to 40 %. These results confirm the efficacy of the proposed approach in enhancing system stability and reliability under dynamic operating conditions, suggesting it as a promising solution for LFC in modern power systems with high renewable energy penetration. • Introduced a PDN-PI cascade controller for LFC in a PV-thermal power system. • Developed hECO-PS algorithm to enhance global exploration and local exploitation. • Achieved lower ITAE values with hECO-PS than conventional methods in various scenarios. • Demonstrated robustness of hECO-PS under fluctuating solar radiation conditions. • Established hECO-PS tuned PDN-PI controller's effectiveness in renewable-rich power systems.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2024-09-20
DOI
https://doi.org/10.1016/j.rineng.2024.102958
Citations
37
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
7.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency regulation of PV-reheat thermal power system via a novel hybrid educational competition optimizer with pattern search and cascaded PDN-PI controller

Mohit Bajaj, Vojtěch Blažek, Özay Can, Serdar Ekinci et al.
37 citations
Results in Engineering
Frequency Control in Power Systems
7.72
article

Frequency regulation of PV-reheat thermal power system via a novel hybrid educational competition optimizer with pattern search and cascaded PDN-PI controller

Mohit Bajaj, Vojtěch Blažek, Özay Can, Serdar Ekinci, Davut İzci
article en
37 citations

Abstract

Maintaining a stable balance between generated power and load demand is a critical challenge in modern power systems, especially with the increasing integration of renewable energy sources like photovoltaic (PV) systems. This study introduces a novel hybrid educational competition optimizer with pattern search (hECO-PS) algorithm to optimally tune a cascaded proportional-derivative with filter and proportional-integral (PDN-PI) controller for load frequency control (LFC) in a two-area power system comprising a PV system and a reheat thermal power system. The proposed hECO-PS algorithm enhances both global exploration and local exploitation capabilities, resulting in superior convergence rates and solution accuracy. The controller's performance was evaluated under various scenarios, including a 10 % step load change and solar radiation variations, demonstrating significant improvements in frequency regulation. The hECO-PS tuned PDN-PI controller achieved a minimum integral of time-weighted absolute error (ITAE) value of 0.4464, outperforming conventional methods like the modified whale optimization algorithm and sea horse algorithm, which yielded ITAE values of 2.6198 and 0.8598, respectively. Furthermore, the proposed controller reduced settling time by up to 46 % and minimized overshoot by up to 40 %. These results confirm the efficacy of the proposed approach in enhancing system stability and reliability under dynamic operating conditions, suggesting it as a promising solution for LFC in modern power systems with high renewable energy penetration. • Introduced a PDN-PI cascade controller for LFC in a PV-thermal power system. • Developed hECO-PS algorithm to enhance global exploration and local exploitation. • Achieved lower ITAE values with hECO-PS than conventional methods in various scenarios. • Demonstrated robustness of hECO-PS under fluctuating solar radiation conditions. • Established hECO-PS tuned PDN-PI controller's effectiveness in renewable-rich power systems.

Results in EngineeringVol. 24
VSB - Technical University of Ostrava (CZ), Applied Science Private University (JO), Recep Tayyip Erdoğan University (TR), Batman University (TR), University of Business and Technology (SA), Graphic Era University (IN), Middle East University (JO)
European Commission
Affordable and clean energy
Openalex Percentile: Top 2%
Frequency Control in Power Systems
7.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.