Seismic Performance of Recycled-Aggregate-Concrete-Based Shear Walls with Concealed Bracing

Relatively few studies have been conducted on the seismic performance of recycled aggregate concrete (RAC) shear walls with concealed bracing. To promote the development of high-performance green building structures and the application of RAC in structural components, the seismic performance of RAC shear walls under different influencing factors was tested, and low-cycle reversed loading tests were performed on ten RAC shear walls with different shear-to-span ratios. The test parameters included the recycled coarse aggregate (RCA) replacement ratio, the recycled fine aggregate (RFA) replacement ratio, the axial compression ratio, the shear span ratio and whether to set up the concealed bracing. The influence of the above variables on the seismic performance was then assessed. The results revealed that the bearing capacity, ductility, stiffness and energy dissipation capacity of the RAC shear walls decreased in line with an increase in the replacement ratio of the RFA. However, the bearing capacity, energy consumption and stiffness of the RAC shear walls decreased within 10% and the ductility decreased within 15%. The RAC shear walls were able to meet the seismic requirements of the building structure after reasonable design and use. As the axial compression ratio increased, the bearing capacity of the RAC shear walls improved, but their elastic–plastic deformation capacity was reduced. Setting the concealed bracing significantly improved the seismic performance of the RAC shear walls, such that they achieved a seismic performance close to that of the natural aggregate concrete (NAC) shear wall. After setting up the concealed bracing, the load carrying capacity of the RAC shear walls increased by up to 15%, the ductility increased by up to 20% and the energy consumption capacity increased by up to 50%. A mechanical calculation model of the RAC shear wall was then established by considering the effect of recycled aggregate, the calculated results of which were a good match with the test results.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-09-20
DOI
https://doi.org/10.3390/buildings14092987
Citations
1
Primary Topic
Recycled Aggregate Concrete Performance
Type
article
Field-Weighted Citation Impact
0.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic Performance of Recycled-Aggregate-Concrete-Based Shear Walls with Concealed Bracing

Wanlin Cao, Jinliang Bian, Yibin Liu, Xin Bao et al.
1 citations
Buildings
Recycled Aggregate Concrete Performance
0.27
article

Seismic Performance of Recycled-Aggregate-Concrete-Based Shear Walls with Concealed Bracing

Wanlin Cao, Jinliang Bian, Yibin Liu, Xin Bao, Zhaoyuan Yang
article en
1 citations

Abstract

Relatively few studies have been conducted on the seismic performance of recycled aggregate concrete (RAC) shear walls with concealed bracing. To promote the development of high-performance green building structures and the application of RAC in structural components, the seismic performance of RAC shear walls under different influencing factors was tested, and low-cycle reversed loading tests were performed on ten RAC shear walls with different shear-to-span ratios. The test parameters included the recycled coarse aggregate (RCA) replacement ratio, the recycled fine aggregate (RFA) replacement ratio, the axial compression ratio, the shear span ratio and whether to set up the concealed bracing. The influence of the above variables on the seismic performance was then assessed. The results revealed that the bearing capacity, ductility, stiffness and energy dissipation capacity of the RAC shear walls decreased in line with an increase in the replacement ratio of the RFA. However, the bearing capacity, energy consumption and stiffness of the RAC shear walls decreased within 10% and the ductility decreased within 15%. The RAC shear walls were able to meet the seismic requirements of the building structure after reasonable design and use. As the axial compression ratio increased, the bearing capacity of the RAC shear walls improved, but their elastic–plastic deformation capacity was reduced. Setting the concealed bracing significantly improved the seismic performance of the RAC shear walls, such that they achieved a seismic performance close to that of the natural aggregate concrete (NAC) shear wall. After setting up the concealed bracing, the load carrying capacity of the RAC shear walls increased by up to 15%, the ductility increased by up to 20% and the energy consumption capacity increased by up to 50%. A mechanical calculation model of the RAC shear wall was then established by considering the effect of recycled aggregate, the calculated results of which were a good match with the test results.

BuildingsVol. 14(9)
Tianjin Chengjian University (CN), Dalian University of Technology (CN), Beijing University of Technology (CN), China State Construction Engineering (China) (CN), Beijing Building Construction Research Institute (China) (CN), Tsinghua University (CN)
Ministry of Science and Technology of the People's Republic of China
Openalex Percentile: Top 44%
Recycled Aggregate Concrete Performance
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.