S2P-Matching: Self-Supervised Patch-Based Matching Using Transformer for Capsule Endoscopic Images Stitching

The Magnetically Controlled Capsule Endoscopy (MCCE) has a limited shooting range, resulting in capturing numerous fragmented images and an inability to precisely locate and examine the region of interest (ROI) as traditional endoscopy can. Addressing this issue, image stitching around the ROI can be employed to aid in the diagnosis of gastrointestinal (GI) tract conditions. However, MCCE images possess unique characteristics, such as weak texture, close-up shooting, and large angle rotation, presenting challenges to current image-matching methods. In this context, a method named S2P-Matching is proposed for self-supervised patch-based matching in MCCE image stitching. The method involves augmenting the raw data by simulating the capsule endoscopic camera's behavior around the GI tract's ROI. Subsequently, an improved contrast learning encoder is utilized to extract local features, represented as deep feature descriptors. This encoder comprises two branches that extract distinct scale features, which are combined over the channel without manual labeling. The data-driven descriptors are then input into a Transformer model to obtain patch-level matches by learning the globally consented matching priors in the pseudo-ground-truth match pairs. Finally, the patch-level matching is refined and filtered to the pixel-level. The experimental results on real-world MCCE images demonstrate that S2P-Matching provides enhanced accuracy in addressing challenging issues in the GI tract environment with image parallax. The performance improvement can reach up to 203 and 55.8% in terms of NCM (Number of Correct Matches) and SR (Success Rate), respectively. This approach is expected to facilitate the wide adoption of MCCE-based gastrointestinal screening.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Engineering
Published
2024-09-20
DOI
https://doi.org/10.1109/tbme.2024.3462502
Citations
5
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
2.32
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S2P-Matching: Self-Supervised Patch-Based Matching Using Transformer for Capsule Endoscopic Images Stitching

Lei Zhu, Hai Jin, Haoyang Chen, Dagan Feng et al.
5 citations
IEEE Transactions on Biomedical Engineering
Gastrointestinal Bleeding Diagnosis and Treatment
2.32
article

S2P-Matching: Self-Supervised Patch-Based Matching Using Transformer for Capsule Endoscopic Images Stitching

Lei Zhu, Hai Jin, Haoyang Chen, Dagan Feng, Dao Zhou, Ping Li, Feng Lü, Bin Sheng, Xiaofei Liao, Tingting Gong, Xianliang Ling, Shuai Liu
article en
5 citations

Abstract

The Magnetically Controlled Capsule Endoscopy (MCCE) has a limited shooting range, resulting in capturing numerous fragmented images and an inability to precisely locate and examine the region of interest (ROI) as traditional endoscopy can. Addressing this issue, image stitching around the ROI can be employed to aid in the diagnosis of gastrointestinal (GI) tract conditions. However, MCCE images possess unique characteristics, such as weak texture, close-up shooting, and large angle rotation, presenting challenges to current image-matching methods. In this context, a method named S2P-Matching is proposed for self-supervised patch-based matching in MCCE image stitching. The method involves augmenting the raw data by simulating the capsule endoscopic camera's behavior around the GI tract's ROI. Subsequently, an improved contrast learning encoder is utilized to extract local features, represented as deep feature descriptors. This encoder comprises two branches that extract distinct scale features, which are combined over the channel without manual labeling. The data-driven descriptors are then input into a Transformer model to obtain patch-level matches by learning the globally consented matching priors in the pseudo-ground-truth match pairs. Finally, the patch-level matching is refined and filtered to the pixel-level. The experimental results on real-world MCCE images demonstrate that S2P-Matching provides enhanced accuracy in addressing challenging issues in the GI tract environment with image parallax. The performance improvement can reach up to 203 and 55.8% in terms of NCM (Number of Correct Matches) and SR (Success Rate), respectively. This approach is expected to facilitate the wide adoption of MCCE-based gastrointestinal screening.

IEEE Transactions on Biomedical EngineeringVol. 72(2)
The University of Sydney (AU), Hong Kong Polytechnic University (HK), Shanghai Jiao Tong University (CN), Hong Kong University of Science and Technology (HK), State Ethnic Affairs Commission (CN), Ruijin Hospital (CN), Huazhong University of Science and Technology (CN), University of Hong Kong (HK)
Openalex Percentile: Top 12%
Gastrointestinal Bleeding Diagnosis and Treatment
2.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.