A Winding-Core High-Frequency Equivalent Circuit Model for Exactly Simulating Partial Discharge Signals Propagation in Transformer

Wideband partial discharge (PD) detection, with its high bandwidth and strong anti-interference capabilities, is an inevitable trend in the development of discharge detection technology. However, the intricate propagation paths and attenuation patterns of high-frequency signals pose challenges for wideband detection of PD, especially in converter transformers. To study the transient response of transformer windings to wideband PD signals, equivalent circuit model is an excellent method. However, conventional equivalent circuit model generally only applies to frequency below 1 MHz. For converter transformers, this equivalent circuit model is insufficient due to strong interference exiting in such frequency band. To solve the problems, this article proposes a winding-core high-frequency equivalent circuit model. Multiple RLC parallel resonant units are added to the circuit model of the interleaved winding, and a transverse capacitance between the high-voltage (HV) winding and the core yoke is also included in the model. Experimental tests on a transformer demonstrate that the improved model can accurately simulate the impedance characteristics of windings up to a frequency of 10 MHz. Compared to the conventional model, the improved model significantly enhances the similarity between simulated signals and measured signals. It can accurately characterize the attenuation of different frequency components within the 10 MHz range, addressing the challenge conventional model faces in simulating signals at the core grounding point.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2024-09-20
DOI
https://doi.org/10.1109/tdei.2024.3464581
Citations
3
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Winding-Core High-Frequency Equivalent Circuit Model for Exactly Simulating Partial Discharge Signals Propagation in Transformer

Zekai Lai, Haibao Mu, Xianjun Shao, Xiaochang Hua et al.
3 citations
IEEE Transactions on Dielectrics and Electrical Insulation
High voltage insulation and dielectric phenomena
0.35
article

A Winding-Core High-Frequency Equivalent Circuit Model for Exactly Simulating Partial Discharge Signals Propagation in Transformer

Zekai Lai, Haibao Mu, Xianjun Shao, Xiaochang Hua, Haofan Lin, Guanjun Zhang, Chenhui Zhou
article en
3 citations

Abstract

Wideband partial discharge (PD) detection, with its high bandwidth and strong anti-interference capabilities, is an inevitable trend in the development of discharge detection technology. However, the intricate propagation paths and attenuation patterns of high-frequency signals pose challenges for wideband detection of PD, especially in converter transformers. To study the transient response of transformer windings to wideband PD signals, equivalent circuit model is an excellent method. However, conventional equivalent circuit model generally only applies to frequency below 1 MHz. For converter transformers, this equivalent circuit model is insufficient due to strong interference exiting in such frequency band. To solve the problems, this article proposes a winding-core high-frequency equivalent circuit model. Multiple RLC parallel resonant units are added to the circuit model of the interleaved winding, and a transverse capacitance between the high-voltage (HV) winding and the core yoke is also included in the model. Experimental tests on a transformer demonstrate that the improved model can accurately simulate the impedance characteristics of windings up to a frequency of 10 MHz. Compared to the conventional model, the improved model significantly enhances the similarity between simulated signals and measured signals. It can accurately characterize the attenuation of different frequency components within the 10 MHz range, addressing the challenge conventional model faces in simulating signals at the core grounding point.

IEEE Transactions on Dielectrics and Electrical InsulationVol. 32(2)
Shanghai Electric (China) (CN), State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 44%
High voltage insulation and dielectric phenomena
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.