An approach to assess real workload of medical linear accelerators in Sri Lanka

Due to the introduction of new radiotherapy treatment techniques and the increased number of cancer patients, there is a higher possibility of redundant workload on radiotherapy machines. Therefore, this study aims to assess the workload in three linear accelerator units. An 8-week survey was conducted in the selected three units, during which all treatment parameters were accumulated. The highest number of treatment sessions per week and highest weekly workload of dose at the isocenter were reported as 465 ± 24 and 1295 ± 93 Gy, respectively in the Varian unit at Apeksha Hospital. The cardinal angle was identified as the 00-300 range in all selected units. The modulation factors for the intensity modulated radiotherapy techniques showed significant variations among the three units. The estimated real weekly workload is quite high compared to previous studies. This study recommends conducting at least a one-year survey, considering all parameters, to obtain more reliable results.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-09-20
DOI
https://doi.org/10.1093/rpd/ncae195
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An approach to assess real workload of medical linear accelerators in Sri Lanka

V. Ramanathan, D. K. Jayaweera, Athukoralalage Dilki Ayodya Dharani Athukorala, Kanthasamy Aravinthan et al.
Radiation Protection Dosimetry
Advanced Radiotherapy Techniques
article

An approach to assess real workload of medical linear accelerators in Sri Lanka

V. Ramanathan, D. K. Jayaweera, Athukoralalage Dilki Ayodya Dharani Athukorala, Kanthasamy Aravinthan, Noorul Jinnah Zeron Anas, A. Ramalingam
article en

Abstract

Due to the introduction of new radiotherapy treatment techniques and the increased number of cancer patients, there is a higher possibility of redundant workload on radiotherapy machines. Therefore, this study aims to assess the workload in three linear accelerator units. An 8-week survey was conducted in the selected three units, during which all treatment parameters were accumulated. The highest number of treatment sessions per week and highest weekly workload of dose at the isocenter were reported as 465 ± 24 and 1295 ± 93 Gy, respectively in the Varian unit at Apeksha Hospital. The cardinal angle was identified as the 00-300 range in all selected units. The modulation factors for the intensity modulated radiotherapy techniques showed significant variations among the three units. The estimated real weekly workload is quite high compared to previous studies. This study recommends conducting at least a one-year survey, considering all parameters, to obtain more reliable results.

Radiation Protection DosimetryVol. 200(19)
General Sir John Kotelawala Defence University (LK), Tellippalai Hospital (LK)
Good health and well-being
Openalex Percentile: Top 79%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.