Artificial intelligence-enhanced wearable technology enables ventricular arrhythmia prediction

Abstract Background and aims Patterns in physical behaviour may be associated with an increased risk of ventricular arrhythmia. We examined associations between temporal dynamics in physical behaviour measured through wearable technology, and the risk of ventricular arrhythmia. Methods The multicenter, prospective SafeHeart study recruited 303 patients with an implantable cardioverter defibrillator (ICD) from May 2021 to September 2022. Continuous physical behaviour data were collected over 365 consecutive days and nights using wearable accelerometers. We characterised each 28-day behavioural time-series using statistical summary indices, and deep representations learned by neural networks. Logistic regression analyses were used to estimate the associations between physical behaviour and the subsequent risk of ventricular arrhythmia as detected by ICD and treated appropriately. Predictive performance was assessed using k-fold cross-validation and quantified by the area under the receiver operating characteristic curve (AUROC). Results From the SafeHeart cohort, 277 patients and 56 ventricular arrhythmia were analysed, contributing to a total of 64,995 days of behavioural data. Reduced numbers of daily physical activity bouts and low day-to-day variation in sleep characteristics were associated with an increased risk of an arrhythmic event. Deep representations improved the predictive performance, with an AUROC of 0.74 ±0.05, compared to statistical summary indices with an AUROC 0.67 ±0.14 (p=0.05 for comparison). Conclusion Our findings suggest that behavioural patterns captured through wearable technology are independently associated with ventricular arrhythmia, particularly when these are characterised by deep representations.

Authors

Institutions

Publication Details

Journal
European Heart Journal - Digital Health
Published
2024-09-21
DOI
https://doi.org/10.1093/ehjdh/ztae069
Citations
3
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial intelligence-enhanced wearable technology enables ventricular arrhythmia prediction

Søren Zöga Diederichsen, Diana My Frodi, Maarten Z H Kolk, Hanno L. Tan et al.
3 citations
European Heart Journal - Digital Health
ECG Monitoring and Analysis
1.21
article

Artificial intelligence-enhanced wearable technology enables ventricular arrhythmia prediction

Søren Zöga Diederichsen, Diana My Frodi, Maarten Z H Kolk, Hanno L. Tan, Jesper Hastrup Svendsen, Reinoud E. Knops, Tariq Osman Andersen, Joss Langford, Niels Risum, Peter Karl Jacobsen, Fleur V.Y. Tjong
article en
3 citations

Abstract

Abstract Background and aims Patterns in physical behaviour may be associated with an increased risk of ventricular arrhythmia. We examined associations between temporal dynamics in physical behaviour measured through wearable technology, and the risk of ventricular arrhythmia. Methods The multicenter, prospective SafeHeart study recruited 303 patients with an implantable cardioverter defibrillator (ICD) from May 2021 to September 2022. Continuous physical behaviour data were collected over 365 consecutive days and nights using wearable accelerometers. We characterised each 28-day behavioural time-series using statistical summary indices, and deep representations learned by neural networks. Logistic regression analyses were used to estimate the associations between physical behaviour and the subsequent risk of ventricular arrhythmia as detected by ICD and treated appropriately. Predictive performance was assessed using k-fold cross-validation and quantified by the area under the receiver operating characteristic curve (AUROC). Results From the SafeHeart cohort, 277 patients and 56 ventricular arrhythmia were analysed, contributing to a total of 64,995 days of behavioural data. Reduced numbers of daily physical activity bouts and low day-to-day variation in sleep characteristics were associated with an increased risk of an arrhythmic event. Deep representations improved the predictive performance, with an AUROC of 0.74 ±0.05, compared to statistical summary indices with an AUROC 0.67 ±0.14 (p=0.05 for comparison). Conclusion Our findings suggest that behavioural patterns captured through wearable technology are independently associated with ventricular arrhythmia, particularly when these are characterised by deep representations.

European Heart Journal - Digital Health
University of Copenhagen (DK), University of Exeter (GB), Copenhagen University Hospital (DK), Rigshospitalet (DK), Netherlands Heart Institute (NL), Amsterdam University Medical Centers (NL), University of Amsterdam (NL)
European Commission, Eurostars
Openalex Percentile: Top 18%
ECG Monitoring and Analysis
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.