A hybrid PCA acceleration method for rapid real-time 2D MRI

<i>Objective.</i>To develop a 2D MR acceleration method utilizing principal component analysis (PCA) in a hybrid fashion for rapid real-time applications.<i>Approach.</i>Retrospective testing was performed on 10 lung, 10 liver and 10 prostate 3T MRI data sets for image quality and target contourability. Sampling of k-space is performed by acquiring central (low-frequency) data in every frame while the high-frequency data is incoherently undersampled such that all of k-space is acquired in a pre-determined number of frames. Firstly, principal components (PCs) representative of intra-frame correlations between central and outer k-space data are used to estimate unsampled data in the frame of interest. Then to add further stability, PCs representative of time-domain fluctuations within a reconstruction window of the most recent frames are fit to outer k-space data (including above estimations) to obtain final estimates in the frame of interest. Accelerated reconstructions between 3x and 8x were tested for image quality and contourability along with the optimal number of PCs for fitting.<i>Main results.</i>It was found that at higher acceleration rates, image quality did not deteriorate significantly. Similarly, it was found that the images were of sufficient quality to contour a target using auto-contouring software at all tested acceleration rates and sites. SSIM values were found to be ⩾0.91 at all accelerations tested. Similarly dice coefficients at the different sites were found to be ⩾0.89 even at 8x accelerations which is on par with or better than intra-observer variation.<i>Significance.</i>This method appears to produce improved image quality and contourability compared to previous PCA methods while also allowing a greater number of PCs to be used in reconstruction. The method can be run using a simple single-channel coil and does not require significant computing power to meet real-time interventional standards (reconstruction times ∼60 ms/frame on Intel i5 CPU).

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-09-20
DOI
https://doi.org/10.1088/1361-6560/ad7dcb
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A hybrid PCA acceleration method for rapid real-time 2D MRI

Nawaid Usmani, Gawon Han, Mark H. Wright, Jihyun Yun et al.
Physics in Medicine and Biology
Advanced MRI Techniques and Applications
article

A hybrid PCA acceleration method for rapid real-time 2D MRI

Nawaid Usmani, Gawon Han, Mark H. Wright, Jihyun Yun, Keith Wachowicz, Zsolt Gabos, B. G. Fallone, Eugene Yip
article en

Abstract

<i>Objective.</i>To develop a 2D MR acceleration method utilizing principal component analysis (PCA) in a hybrid fashion for rapid real-time applications.<i>Approach.</i>Retrospective testing was performed on 10 lung, 10 liver and 10 prostate 3T MRI data sets for image quality and target contourability. Sampling of k-space is performed by acquiring central (low-frequency) data in every frame while the high-frequency data is incoherently undersampled such that all of k-space is acquired in a pre-determined number of frames. Firstly, principal components (PCs) representative of intra-frame correlations between central and outer k-space data are used to estimate unsampled data in the frame of interest. Then to add further stability, PCs representative of time-domain fluctuations within a reconstruction window of the most recent frames are fit to outer k-space data (including above estimations) to obtain final estimates in the frame of interest. Accelerated reconstructions between 3x and 8x were tested for image quality and contourability along with the optimal number of PCs for fitting.<i>Main results.</i>It was found that at higher acceleration rates, image quality did not deteriorate significantly. Similarly, it was found that the images were of sufficient quality to contour a target using auto-contouring software at all tested acceleration rates and sites. SSIM values were found to be ⩾0.91 at all accelerations tested. Similarly dice coefficients at the different sites were found to be ⩾0.89 even at 8x accelerations which is on par with or better than intra-observer variation.<i>Significance.</i>This method appears to produce improved image quality and contourability compared to previous PCA methods while also allowing a greater number of PCs to be used in reconstruction. The method can be run using a simple single-channel coil and does not require significant computing power to meet real-time interventional standards (reconstruction times ∼60 ms/frame on Intel i5 CPU).

Physics in Medicine and BiologyVol. 69(20)
University of Alberta (CA)
Openalex Percentile: Top 74%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.