Radon exhalation rate from the latex pillows and its potential exposure to users

To develop a new system to accurately measure the radon exhalation from the latex pillows, and to estimate its potential exposure to users. The new system is composed of two loops, the first loop is designed to trap background radon and thoron until their levels are nearly zero, and the second loop is the measurement loop to detect radon and thoron exhalation rates from the pillows. The results showed that mass radon exhalation rated ranged from 0.18 Bq·kg −1 ⋅h −1 to 0.78 Bq·kg −1 ⋅h −1 , with an average of (0.36 ​± ​0.17) Bq·kg −1 ⋅h −1 in the 9 samples. The average annual effective dose to users in a model room was estimated to be (15.51 ​± ​12.69) μSv by assuming two pillows was used. These results demonstrate that the new system can effectively measure radon exhalation rates in latex pillows, and the potential exposure to radon exhalating from the pillows is very low.

Authors

Institutions

Publication Details

Journal
Radiation Medicine and Protection
Published
2024-09-20
DOI
https://doi.org/10.1016/j.radmp.2024.09.003
Citations
1
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.45
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radon exhalation rate from the latex pillows and its potential exposure to users

Masahiro Hosoda, Shinji Tokonami, Rawiwan Kritsananuwat, Vichai Puripunyavanich et al.
1 citations
Radiation Medicine and Protection
Radioactivity and Radon Measurements
0.45
article

Radon exhalation rate from the latex pillows and its potential exposure to users

Masahiro Hosoda, Shinji Tokonami, Rawiwan Kritsananuwat, Vichai Puripunyavanich, Kanokporn Boonsirichai, Santi Raksawong, Chutima Kranrod, Hirofumi Tazoe, Ritiron Samran, Phachirarat Sola, Pimprapa Chaijak, Sattawat Jongjitklang, Waleeporn Pongkua
article en
1 citations

Abstract

To develop a new system to accurately measure the radon exhalation from the latex pillows, and to estimate its potential exposure to users. The new system is composed of two loops, the first loop is designed to trap background radon and thoron until their levels are nearly zero, and the second loop is the measurement loop to detect radon and thoron exhalation rates from the pillows. The results showed that mass radon exhalation rated ranged from 0.18 Bq·kg −1 ⋅h −1 to 0.78 Bq·kg −1 ⋅h −1 , with an average of (0.36 ​± ​0.17) Bq·kg −1 ⋅h −1 in the 9 samples. The average annual effective dose to users in a model room was estimated to be (15.51 ​± ​12.69) μSv by assuming two pillows was used. These results demonstrate that the new system can effectively measure radon exhalation rates in latex pillows, and the potential exposure to radon exhalating from the pillows is very low.

Radiation Medicine and ProtectionVol. 5(4)
Hirosaki University (JP), Chulalongkorn University (TH), Muban Chombueng Rajabhat University (TH), Charoenkrung Pracharak Hospital (TH), Thaksin University (TH)
Zero hunger
Openalex Percentile: Top 36%
Radioactivity and Radon Measurements
0.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.