A benchmark of muscle models to length changes great and small

Digital human body models are used to simulate injuries that occur as a result of vehicle collisions, vibration, sports, and falls. Given enough time the body's musculature can generate force, affect the body's movements, and change the risk of some injuries. The finite-element code LS-DYNA is often used to simulate the movements and injuries sustained by the digital human body models as a result of an accident. In this work, we evaluate the accuracy of the three muscle models in LS-DYNA (MAT_156, EHTM, and the VEXAT) when simulating a range of experiments performed on isolated muscle: force-length-velocity experiments on maximally and sub-maximally stimulated muscle, active-lengthening experiments, and vibration experiments. The force-length-velocity experiments are included because these conditions are typical of the muscle activity that precedes an accident, while the active-lengthening and vibration experiments mimic conditions that can cause injury. The three models perform similarly during the maximally and sub-maximally activated force-length-velocity experiments, but noticeably differ in response to the active-lengthening and vibration experiments. The VEXAT model is able to generate the enhanced forces of biological muscle during active lengthening, while both the MAT_156 and EHTM produce too little force. In response to vibration, the stiffness and damping of the VEXAT model closely follows the experimental data while the MAT_156 and EHTM models differ substantially. The accuracy of the VEXAT model comes from two additional mechanical structures that are missing in the MAT_156 and EHTM models: viscoelastic cross-bridges, and an active titin filament. To help others build on our work we have made our simulation code publicly available.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2024-09-20
DOI
https://doi.org/10.1016/j.jmbbm.2024.106740
Citations
1
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A benchmark of muscle models to length changes great and small

Matthew Millard, Tobias Siebert, Norman Stutzig, Jörg Fehr
1 citations
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Muscle activation and electromyography studies
0.18
article

A benchmark of muscle models to length changes great and small

Matthew Millard, Tobias Siebert, Norman Stutzig, Jörg Fehr
article en
1 citations

Abstract

Digital human body models are used to simulate injuries that occur as a result of vehicle collisions, vibration, sports, and falls. Given enough time the body's musculature can generate force, affect the body's movements, and change the risk of some injuries. The finite-element code LS-DYNA is often used to simulate the movements and injuries sustained by the digital human body models as a result of an accident. In this work, we evaluate the accuracy of the three muscle models in LS-DYNA (MAT_156, EHTM, and the VEXAT) when simulating a range of experiments performed on isolated muscle: force-length-velocity experiments on maximally and sub-maximally stimulated muscle, active-lengthening experiments, and vibration experiments. The force-length-velocity experiments are included because these conditions are typical of the muscle activity that precedes an accident, while the active-lengthening and vibration experiments mimic conditions that can cause injury. The three models perform similarly during the maximally and sub-maximally activated force-length-velocity experiments, but noticeably differ in response to the active-lengthening and vibration experiments. The VEXAT model is able to generate the enhanced forces of biological muscle during active lengthening, while both the MAT_156 and EHTM produce too little force. In response to vibration, the stiffness and damping of the VEXAT model closely follows the experimental data while the MAT_156 and EHTM models differ substantially. The accuracy of the VEXAT model comes from two additional mechanical structures that are missing in the MAT_156 and EHTM models: viscoelastic cross-bridges, and an active titin filament. To help others build on our work we have made our simulation code publicly available.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 160
University of Stuttgart (DE)
Deutsche Forschungsgemeinschaft, Stuttgart Center for Simulation Science, Universität Stuttgart
Openalex Percentile: Top 53%
Muscle activation and electromyography studies
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.