Simultaneous Accelerometer And Self-Report Logs Improve Data Fidelity And Accuracy

PURPOSE: Cardiovascular (CV) disease is a global health issue and leading cause of death in the U.S.1 Major contributors to poor CV health are insufficient physical activity (PA) and sleep. Reduced PA leads to increased systemic inflammation, blood pressure, depression, morbidity, and mortality.2,3,6 Reduced sleep contributes to onset and worsening of cardio-metabolic disorders.4,5 Current methods measuring PA and sleep vary in accuracy. Actigraphy is the gold standard, yet issues delineating daytime PA from nighttime motion occur. The purpose of this analysis was to compare the accuracy of a self-report sleep diary with accelerometer measured sleep. METHODS: We conducted a secondary analysis of a three-arm RCT in adults recovering from major cardiac events. Measurements included an 8-day wrist worn accelerometer and an investigator developed in-bed/wake time self-report. Auto-detected accelerometer sleep times were compared to self-report in-bed/wake times. Self-report rounding was evaluated at 1, 5, 10, 15, 30, or 60-minute increments. Descriptive analysis compared self-report and accelerometer measured PA and self-report at baseline (T0), 10 weeks (T1), and 18 weeks (T2). RESULTS: At T0 39 individuals consented and completed measurements. Participants were primarily men (58%), non-Hispanic white (89%), and had mean age of 61. Follow-up measures were completed by 22 participants at T1 and 24 at T2. Total completion of the self-report activity diary remained high (87% and 92%) at T1 and T2. Most participants used specific 1-minute increments in self-report. 100% of participants needed at least 1 accelerometer measured sleep/wake-time adjusted to match self-report. CONCLUSION: This project demonstrates the importance of both subjective and objective measures when evaluating sleep to verify accuracy of data. Historically, self-report was needed to avoid over estimations of sleep or under estimations of wake time. Findings show participants are willing to utilize activity diaries and PA tracking at follow-up with high completion rates and specificity in self-report. Future work should consider the use of subjective measurement tools paired with emerging technology to objectively measure PA and sleep accurately. Clinically, a self-report may be sufficient to identify disturbed sleep. IU CEQL, Sigma Theta Tau (Alpha & International), Jonas Philanthropies, Indiana University Research Support Funds & School of Nursing

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2024-09-16
DOI
https://doi.org/10.1249/01.mss.0001061456.99522.71
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Accelerometer And Self-Report Logs Improve Data Fidelity And Accuracy

Anna Förster, Kelly Wierenga
Medicine & Science in Sports & Exercise
Sensor Technology and Measurement Systems
article

Simultaneous Accelerometer And Self-Report Logs Improve Data Fidelity And Accuracy

Anna Förster, Kelly Wierenga
article en

Abstract

PURPOSE: Cardiovascular (CV) disease is a global health issue and leading cause of death in the U.S.1 Major contributors to poor CV health are insufficient physical activity (PA) and sleep. Reduced PA leads to increased systemic inflammation, blood pressure, depression, morbidity, and mortality.2,3,6 Reduced sleep contributes to onset and worsening of cardio-metabolic disorders.4,5 Current methods measuring PA and sleep vary in accuracy. Actigraphy is the gold standard, yet issues delineating daytime PA from nighttime motion occur. The purpose of this analysis was to compare the accuracy of a self-report sleep diary with accelerometer measured sleep. METHODS: We conducted a secondary analysis of a three-arm RCT in adults recovering from major cardiac events. Measurements included an 8-day wrist worn accelerometer and an investigator developed in-bed/wake time self-report. Auto-detected accelerometer sleep times were compared to self-report in-bed/wake times. Self-report rounding was evaluated at 1, 5, 10, 15, 30, or 60-minute increments. Descriptive analysis compared self-report and accelerometer measured PA and self-report at baseline (T0), 10 weeks (T1), and 18 weeks (T2). RESULTS: At T0 39 individuals consented and completed measurements. Participants were primarily men (58%), non-Hispanic white (89%), and had mean age of 61. Follow-up measures were completed by 22 participants at T1 and 24 at T2. Total completion of the self-report activity diary remained high (87% and 92%) at T1 and T2. Most participants used specific 1-minute increments in self-report. 100% of participants needed at least 1 accelerometer measured sleep/wake-time adjusted to match self-report. CONCLUSION: This project demonstrates the importance of both subjective and objective measures when evaluating sleep to verify accuracy of data. Historically, self-report was needed to avoid over estimations of sleep or under estimations of wake time. Findings show participants are willing to utilize activity diaries and PA tracking at follow-up with high completion rates and specificity in self-report. Future work should consider the use of subjective measurement tools paired with emerging technology to objectively measure PA and sleep accurately. Clinically, a self-report may be sufficient to identify disturbed sleep. IU CEQL, Sigma Theta Tau (Alpha & International), Jonas Philanthropies, Indiana University Research Support Funds & School of Nursing

Medicine & Science in Sports & ExerciseVol. 56(10S)
Indiana University – Purdue University Indianapolis (US)
Openalex Percentile: Top 83%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.