Consumer Wearable-based Vo2max Estimates Compared To Metabolic Cart During A Training Intervention

Tracking health and fitness information is more accessible and comprehensive due to the prevalence of wearable technology. Many devices provide estimations of VO2max, a key determinant of cardiovascular fitness and aerobic performance. PURPOSE: To compare the validity and reliability of wearable-based (Garmin & Polar) methods of estimating VO2max to a gold-standard measurement (indirect calorimetry). METHODS: 47 active-duty Air Force personnel (n = 47; males = 34, females = 13) completed a treadmill VO2max test before and after a 12-week training intervention. Before completing the lab test, participants completed the supine orthostatic Polar Fitness Test on the Polar GritX Pro watch to estimate VO2max. Within 5 days of the lab test, participants completed a 1.5-mile Cooper Test while wearing a Garmin Fenix 6 watch and a Polar H10 chest strap to generate a VO2max estimate. RESULTS: Mean absolute percentage error (MAPE) and Lin’s Concordance (CCC) were assessed for both Garmin (MAPE: 9.4%; CCC: 0.63) and Polar (MAPE: 12.0%; CCC: 0.46). After training, there was a significant increase in VO2max as measured by the metabolic cart (3.19 ml/kg/min ± 1.96; p < 0.01), but no significant changes were detected by Garmin (-0.13 ml/kg/min ± 0.18; p = 0.74) or Polar (0.19 ml/kg/min ± 0.73; p = 0.71). Likewise, when participants who experienced at least an 8% increase in VO2max (p < 0.01) were analyzed separately, neither Garmin nor Polar demonstrated any changes in VO2max estimate. CONCLUSIONS: VO2max estimates from both Garmin and Polar were not accurate at single time points and did not detect significant changes in actual VO2max over time.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2024-09-16
DOI
https://doi.org/10.1249/01.mss.0001056008.09729.2f
Primary Topic
Cardiovascular and exercise physiology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Consumer Wearable-based Vo2max Estimates Compared To Metabolic Cart During A Training Intervention

Kristyn Barrett, Robert A. Briggs, Jason J. Eckerle, Maegan L. O’Connor et al.
Medicine & Science in Sports & Exercise
Cardiovascular and exercise physiology
article

Consumer Wearable-based Vo2max Estimates Compared To Metabolic Cart During A Training Intervention

Kristyn Barrett, Robert A. Briggs, Jason J. Eckerle, Maegan L. O’Connor, Michael B. Dial, Joshua A. Hagen, Nicole T. Ray, Adam J. Strang, James R. Walters
article en

Abstract

Tracking health and fitness information is more accessible and comprehensive due to the prevalence of wearable technology. Many devices provide estimations of VO2max, a key determinant of cardiovascular fitness and aerobic performance. PURPOSE: To compare the validity and reliability of wearable-based (Garmin & Polar) methods of estimating VO2max to a gold-standard measurement (indirect calorimetry). METHODS: 47 active-duty Air Force personnel (n = 47; males = 34, females = 13) completed a treadmill VO2max test before and after a 12-week training intervention. Before completing the lab test, participants completed the supine orthostatic Polar Fitness Test on the Polar GritX Pro watch to estimate VO2max. Within 5 days of the lab test, participants completed a 1.5-mile Cooper Test while wearing a Garmin Fenix 6 watch and a Polar H10 chest strap to generate a VO2max estimate. RESULTS: Mean absolute percentage error (MAPE) and Lin’s Concordance (CCC) were assessed for both Garmin (MAPE: 9.4%; CCC: 0.63) and Polar (MAPE: 12.0%; CCC: 0.46). After training, there was a significant increase in VO2max as measured by the metabolic cart (3.19 ml/kg/min ± 1.96; p < 0.01), but no significant changes were detected by Garmin (-0.13 ml/kg/min ± 0.18; p = 0.74) or Polar (0.19 ml/kg/min ± 0.73; p = 0.71). Likewise, when participants who experienced at least an 8% increase in VO2max (p < 0.01) were analyzed separately, neither Garmin nor Polar demonstrated any changes in VO2max estimate. CONCLUSIONS: VO2max estimates from both Garmin and Polar were not accurate at single time points and did not detect significant changes in actual VO2max over time.

Medicine & Science in Sports & ExerciseVol. 56(10S)
Wright-Patterson Air Force Base (US), The Ohio State University (US)
Openalex Percentile: Top 69%
Cardiovascular and exercise physiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.