Accuracy Of Step Counting Methods: The Skyrocket Study

The Consumer Technology Association (CTA) recommends at least two researchers verify, through video recordings, observed steps taken during treadmill-based validation studies of wearable technologies. To our knowledge, there is no evidence to support this recommendation. The duplicative efforts of performing additional recounts to enhance reliability requires significant resources to cover personnel time and costs. PURPOSE: To analyze whether additional reviews of video recordings are necessary to verify observed steps counted during treadmill testing. METHODS: Twenty treadmill walking bouts (ranging in speeds from 0.5mph to 4.0mph) were randomly selected from a larger sample performed by 18-20-year-old participants in the NIH-funded R01 SKyRoCKeT Study of cadence and intensity. Directly observed, hand-tallied steps taken during the bouts served as the original step count. Video recordings were reviewed and recounted by a second researcher. To implement the CTA recommendations, a third, independent researcher conducted a third count on the first five walking bouts. Mean absolute percentage deviation (MAPD = 1/n Σ | (recount - original)/original| x 100%) was calculated, where n was the number of bouts. RESULTS: The MAPD was 0.09% with bout-specific deviations ranging between 0 - 0.97%, indicating that there was less than a 1% difference between the original and first recount for the same bout. The biggest difference between the original and first recount was 6 steps in a single five-minute walking bout at 4.0mph resulting in a 0.97% deviation compared to the original count. The third recount produced a 0% deviation between the two recounts. CONCLUSIONS: Although a second recount of video recorded steps has been previously recommended, the calculated MAPD value showed an average deviation of less than 0.1% across all recounts. Multiple recounts of observed steps taken during treadmill-based studies are redundant given the apparently very low deviations identified from an original count. This information is useful for planning large-scale studies considering the personnel time and costs involved. NIH NICHD - R01HD105768

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2024-09-16
DOI
https://doi.org/10.1249/01.mss.0001056044.34387.10
Primary Topic
Time Series Analysis and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy Of Step Counting Methods: The Skyrocket Study

Trudy Moore-Harrison, Catrine Tudor‐Locke, Mariya Boikova, Cayla R. McAvoy et al.
Medicine & Science in Sports & Exercise
Time Series Analysis and Forecasting
article

Accuracy Of Step Counting Methods: The Skyrocket Study

Trudy Moore-Harrison, Catrine Tudor‐Locke, Mariya Boikova, Cayla R. McAvoy, Laura H. Gunn, Taylor Fiorentino, Agnes Bucko, Michael Dulin
article en

Abstract

The Consumer Technology Association (CTA) recommends at least two researchers verify, through video recordings, observed steps taken during treadmill-based validation studies of wearable technologies. To our knowledge, there is no evidence to support this recommendation. The duplicative efforts of performing additional recounts to enhance reliability requires significant resources to cover personnel time and costs. PURPOSE: To analyze whether additional reviews of video recordings are necessary to verify observed steps counted during treadmill testing. METHODS: Twenty treadmill walking bouts (ranging in speeds from 0.5mph to 4.0mph) were randomly selected from a larger sample performed by 18-20-year-old participants in the NIH-funded R01 SKyRoCKeT Study of cadence and intensity. Directly observed, hand-tallied steps taken during the bouts served as the original step count. Video recordings were reviewed and recounted by a second researcher. To implement the CTA recommendations, a third, independent researcher conducted a third count on the first five walking bouts. Mean absolute percentage deviation (MAPD = 1/n Σ | (recount - original)/original| x 100%) was calculated, where n was the number of bouts. RESULTS: The MAPD was 0.09% with bout-specific deviations ranging between 0 - 0.97%, indicating that there was less than a 1% difference between the original and first recount for the same bout. The biggest difference between the original and first recount was 6 steps in a single five-minute walking bout at 4.0mph resulting in a 0.97% deviation compared to the original count. The third recount produced a 0% deviation between the two recounts. CONCLUSIONS: Although a second recount of video recorded steps has been previously recommended, the calculated MAPD value showed an average deviation of less than 0.1% across all recounts. Multiple recounts of observed steps taken during treadmill-based studies are redundant given the apparently very low deviations identified from an original count. This information is useful for planning large-scale studies considering the personnel time and costs involved. NIH NICHD - R01HD105768

Medicine & Science in Sports & ExerciseVol. 56(10S)
University of North Carolina at Charlotte (US)
Climate action
Openalex Percentile: Top 83%
Time Series Analysis and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.