Examining The Test-retest Reliability Of A Sit To Stand Power Test In Individuals With Cancer

EXAMINING THE TEST-RETEST RELIABILITY OF A SIT TO STAND POWER TEST IN INDIVIDUALS WITH CANCERKenneth S Anderson, Alexander M Brooks, Olivia R Kocuba, Kylah E Jackson, Shana E Harrington, Ciaran M FairmanUniversity of South Carolina It is well documented that individuals with cancer experience pronounced reductions in physical function and muscle strength as a consequence of cancer treatments. However, it is being increasingly recognized that muscle power can also be substantially affected, which is important given the role of lower body power in fall prevention in older adults. The identification of quick and inexpensive tests of lower body muscle power could provide greater insight into changes in skeletal muscle quality from cancer treatments. PURPOSE: To assess the test-retest reliability, and measurement error of a sit-to-stand power test in individuals with cancer. METHODS: 19 individuals with cancer completed two sit-to-stand power tests, each separated by 2-5 days. Sit to stand power test is administered by having the participant sit in a chair with feet flat on the floor and standing up as quickly as possible while tethered to a power analyzer.The test-retest reliability was assessed using intraclass correlation coefficient (ICC), with an ICC ≥0.75 considered sufficient. Measurement error was established by calculating the standard error of measurement (SEM) and minimal detectable change (MDC). All analysis were performed using R (Version 3.3.0). RESULTS: The majority (95%) (n = 19) of participants were female, with 79% (n = 15) previously treated for breast cancer. Characteristics of participants were as follows: age: 63 ± 8 yrs, height: 65 ± 3.2 in, and weight: 80.0 ± 15.5 kg. The ICC [1,2] for the sit-to-stand power test was 0.9 (95% CI: 0.75-0.96). The SEM was 201.48 W and the MDC was 558.47 W. CONCLUSIONs: Our results indicate that the sit-to-stand power test is a reliable measure of lower body muscular power in individuals with cancer. Therefore, this test could be considered as a quick and inexpensive method of tracking changes in lower body power in oncology care. Further, our measures of SEM and MDC can provide insight when interpreting changes in this assessment in individuals with cancer.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2024-09-16
DOI
https://doi.org/10.1249/01.mss.0001062092.60590.6f
Primary Topic
Childhood Cancer Survivors' Quality of Life
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Examining The Test-retest Reliability Of A Sit To Stand Power Test In Individuals With Cancer

Shana Harrington, Ciaran M. Fairman, Olivia R. Kocuba, Alexander M. Brooks et al.
Medicine & Science in Sports & Exercise
Childhood Cancer Survivors' Quality of Life
article

Examining The Test-retest Reliability Of A Sit To Stand Power Test In Individuals With Cancer

Shana Harrington, Ciaran M. Fairman, Olivia R. Kocuba, Alexander M. Brooks, Kenneth S. Anderson, Kylah E. Jackson
article en

Abstract

EXAMINING THE TEST-RETEST RELIABILITY OF A SIT TO STAND POWER TEST IN INDIVIDUALS WITH CANCERKenneth S Anderson, Alexander M Brooks, Olivia R Kocuba, Kylah E Jackson, Shana E Harrington, Ciaran M FairmanUniversity of South Carolina It is well documented that individuals with cancer experience pronounced reductions in physical function and muscle strength as a consequence of cancer treatments. However, it is being increasingly recognized that muscle power can also be substantially affected, which is important given the role of lower body power in fall prevention in older adults. The identification of quick and inexpensive tests of lower body muscle power could provide greater insight into changes in skeletal muscle quality from cancer treatments. PURPOSE: To assess the test-retest reliability, and measurement error of a sit-to-stand power test in individuals with cancer. METHODS: 19 individuals with cancer completed two sit-to-stand power tests, each separated by 2-5 days. Sit to stand power test is administered by having the participant sit in a chair with feet flat on the floor and standing up as quickly as possible while tethered to a power analyzer.The test-retest reliability was assessed using intraclass correlation coefficient (ICC), with an ICC ≥0.75 considered sufficient. Measurement error was established by calculating the standard error of measurement (SEM) and minimal detectable change (MDC). All analysis were performed using R (Version 3.3.0). RESULTS: The majority (95%) (n = 19) of participants were female, with 79% (n = 15) previously treated for breast cancer. Characteristics of participants were as follows: age: 63 ± 8 yrs, height: 65 ± 3.2 in, and weight: 80.0 ± 15.5 kg. The ICC [1,2] for the sit-to-stand power test was 0.9 (95% CI: 0.75-0.96). The SEM was 201.48 W and the MDC was 558.47 W. CONCLUSIONs: Our results indicate that the sit-to-stand power test is a reliable measure of lower body muscular power in individuals with cancer. Therefore, this test could be considered as a quick and inexpensive method of tracking changes in lower body power in oncology care. Further, our measures of SEM and MDC can provide insight when interpreting changes in this assessment in individuals with cancer.

Medicine & Science in Sports & ExerciseVol. 56(10S)
University of South Carolina (US)
Openalex Percentile: Top 75%
Childhood Cancer Survivors' Quality of Life
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.