Markerless Vs. Marker-based Kinematics During 45-degree Cutting In Pediatric Patients

PURPOSE: Sports biomechanical analysis has traditionally been performed using marker-based motion analysis. Markerless motion capture systems are now available, but need to be validated for clinical and research use. This study compares kinematics from the Theia3D markerless system vs. the Vicon marker-based system for cutting in pediatric patients. METHODS: 10 pediatric athletes (6 female; age range 10-18 years) with lower extremity injuries (5 ACL, 1 MCL, 4 lower limb pain, 1 unspecified knee injury) underwent sports biomechanical testing with data being captured concurrently by a traditional marker-based motion capture system (Nexus2, Vicon, Oxford, UK) and a markerless system (Theia3D, Ontario, Canada and Qualysis, Goteborg, Sweden). Participants performed a 45° cut by running straight forward, planting their left foot on a force plate, and cutting to the right along a guideline on the floor. Kinematic data from one successful trial per patient was compared between the markerless and marker-based systems using root mean square difference (RMSD), mean difference, and RMSD after subtracting the mean difference (RMSDoffset). RESULTS: Kinematics showed similar patterns between the markerless and marker-based systems. While average RMSD of the raw data was >5° for most joint angles, all RMSDoffset were < 7° except for trunk and hip rotation (9.7° and 7.5°, respectively) (Table). Systematic differences between the two systems >10° were observed in trunk tilt and ankle inversion/eversion with differences >5° in ankle rotation, knee rotation, and knee flexion/extension. CONCLUSIONS: The markerless system produced kinematic patterns similar to marker-based motion analysis during cutting, but the differences were greater than observed during gait1 and not always systematic. Additional validation of accuracy and reliability is recommended before markerless motion capture is used for clinical biomechanical sports assessment. 1 Wren 2023. Gait Pos 104, 9-14

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2024-09-16
DOI
https://doi.org/10.1249/01.mss.0001061244.86420.ab
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Markerless Vs. Marker-based Kinematics During 45-degree Cutting In Pediatric Patients

Shawn M. Roberts, Tishya A. L. Wren, Eva Ciccodicola, Avery Lee
Medicine & Science in Sports & Exercise
Shoulder Injury and Treatment
article

Markerless Vs. Marker-based Kinematics During 45-degree Cutting In Pediatric Patients

Shawn M. Roberts, Tishya A. L. Wren, Eva Ciccodicola, Avery Lee
article en

Abstract

PURPOSE: Sports biomechanical analysis has traditionally been performed using marker-based motion analysis. Markerless motion capture systems are now available, but need to be validated for clinical and research use. This study compares kinematics from the Theia3D markerless system vs. the Vicon marker-based system for cutting in pediatric patients. METHODS: 10 pediatric athletes (6 female; age range 10-18 years) with lower extremity injuries (5 ACL, 1 MCL, 4 lower limb pain, 1 unspecified knee injury) underwent sports biomechanical testing with data being captured concurrently by a traditional marker-based motion capture system (Nexus2, Vicon, Oxford, UK) and a markerless system (Theia3D, Ontario, Canada and Qualysis, Goteborg, Sweden). Participants performed a 45° cut by running straight forward, planting their left foot on a force plate, and cutting to the right along a guideline on the floor. Kinematic data from one successful trial per patient was compared between the markerless and marker-based systems using root mean square difference (RMSD), mean difference, and RMSD after subtracting the mean difference (RMSDoffset). RESULTS: Kinematics showed similar patterns between the markerless and marker-based systems. While average RMSD of the raw data was >5° for most joint angles, all RMSDoffset were < 7° except for trunk and hip rotation (9.7° and 7.5°, respectively) (Table). Systematic differences between the two systems >10° were observed in trunk tilt and ankle inversion/eversion with differences >5° in ankle rotation, knee rotation, and knee flexion/extension. CONCLUSIONS: The markerless system produced kinematic patterns similar to marker-based motion analysis during cutting, but the differences were greater than observed during gait1 and not always systematic. Additional validation of accuracy and reliability is recommended before markerless motion capture is used for clinical biomechanical sports assessment. 1 Wren 2023. Gait Pos 104, 9-14

Medicine & Science in Sports & ExerciseVol. 56(10S)
Children's Hospital of Los Angeles (US)
Openalex Percentile: Top 71%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.