Comparison Of Running Gait Variability During Treadmill Versus Overground Running Using Lace-mounted Wearable Sensors

Instrumented laboratory running analyses are the gold standard for gait assessment but may not accurately capture the variability of overground running. Consumer-grade wearable sensors enable running gait analyses during indoor and outdoor training and allow for comparisons of biomechanical variability across environments. PURPOSE: Assess variability and limb differences in spatiotemporal, kinetic, and kinematic running biomechanics between- and within- treadmill and overground running over a 5 km distance. METHODS: 51 recreational runners (22F, 29 M; age: 37 ± 11 years; BMI: 22.9 ± 3.6 kg/m2) completed an outdoor 5 km run on a level standardized route followed by a 5 km treadmill run 13.7 ± 4.7 days apart. Participants ran at self-selected moderate training paces (3.5 ± 1.0 m/s) with bilateral lace-mounted wearable sensors. Sensor-derived metrics included spatiotemporal, kinetic, and kinematic measures. Runs were filtered to remove walking data (flight ratio < 10%) and segmented into thirds by time. Coefficients of Variation (CV) were calculated for all metrics to determine variability ([Standard Deviation/Mean] *100). General linear models were used to compare average biomechanics and CV between run environments and limbs, and changes across three equal run segments, covarying for pace. RESULTS: Spatiotemporal, kinetic, and kinematic mean outcomes differed significantly between environments (p < 0.001; Table). Stride length was significantly longer in the first versus other run segments (Mean Difference [MD] range: 2.7-3.4 m; p < 0.001). CVs were significantly higher for most metrics during indoor running (MD range: 0.26-3.78, p-range: < 0.001-0.02; Table). No significant interlimb differences were noted. CONCLUSIONS: Increased running gait variability during indoor running may be a result of adaptations to fit the physical constraints of a treadmill system compared to overground level running. This study was funded by Samsung Electronics Co., LTD.This study was funded by Samsung Electronics Co., LTD.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2024-09-16
DOI
https://doi.org/10.1249/01.mss.0001057824.80662.00
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison Of Running Gait Variability During Treadmill Versus Overground Running Using Lace-mounted Wearable Sensors

Adam S. Lepley, Alexandra F. DeJong Lempke, Marni G. Wasserman, Kenneth M. Kozloff et al.
Medicine & Science in Sports & Exercise
Lower Extremity Biomechanics and Pathologies
article

Comparison Of Running Gait Variability During Treadmill Versus Overground Running Using Lace-mounted Wearable Sensors

Adam S. Lepley, Alexandra F. DeJong Lempke, Marni G. Wasserman, Kenneth M. Kozloff, Amanda C. Melvin, Adam P. Audet
article en

Abstract

Instrumented laboratory running analyses are the gold standard for gait assessment but may not accurately capture the variability of overground running. Consumer-grade wearable sensors enable running gait analyses during indoor and outdoor training and allow for comparisons of biomechanical variability across environments. PURPOSE: Assess variability and limb differences in spatiotemporal, kinetic, and kinematic running biomechanics between- and within- treadmill and overground running over a 5 km distance. METHODS: 51 recreational runners (22F, 29 M; age: 37 ± 11 years; BMI: 22.9 ± 3.6 kg/m2) completed an outdoor 5 km run on a level standardized route followed by a 5 km treadmill run 13.7 ± 4.7 days apart. Participants ran at self-selected moderate training paces (3.5 ± 1.0 m/s) with bilateral lace-mounted wearable sensors. Sensor-derived metrics included spatiotemporal, kinetic, and kinematic measures. Runs were filtered to remove walking data (flight ratio < 10%) and segmented into thirds by time. Coefficients of Variation (CV) were calculated for all metrics to determine variability ([Standard Deviation/Mean] *100). General linear models were used to compare average biomechanics and CV between run environments and limbs, and changes across three equal run segments, covarying for pace. RESULTS: Spatiotemporal, kinetic, and kinematic mean outcomes differed significantly between environments (p < 0.001; Table). Stride length was significantly longer in the first versus other run segments (Mean Difference [MD] range: 2.7-3.4 m; p < 0.001). CVs were significantly higher for most metrics during indoor running (MD range: 0.26-3.78, p-range: < 0.001-0.02; Table). No significant interlimb differences were noted. CONCLUSIONS: Increased running gait variability during indoor running may be a result of adaptations to fit the physical constraints of a treadmill system compared to overground level running. This study was funded by Samsung Electronics Co., LTD.This study was funded by Samsung Electronics Co., LTD.

Medicine & Science in Sports & ExerciseVol. 56(10S)
University of Michigan (US)
Openalex Percentile: Top 86%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.