BACKGROUND: Markerless motion capture is a rapidly advancing technology and has been tested indoors and proven reliable. However, there are no studies that have tested a portable markerless motion capture system outdoors and out of the lab setting. The purpose of this study is to determine test-retest reliability of knee kinematics using a portable markerless motion capture system during a walking test in healthy adults. METHODS: Twenty-one participants (6 M, 15F, age = 23.1 ± 1.8 years, height = 167.1 ± 7.8 cm, mass = 69.8 ± 23.1 kg) performed two walking tests each separated by five days. Participants walked at a comfortable pace for eight trials while being recorded at 60 Hz. After collection, video data was exported and reduced in a markerless motion capture software. Maximum and minimum knee and hip kinematics were collected during the first 50% of stance phase. Test-retest reliability was calculated with intraclass correlation coefficients (ICCs) between testing time 1 and time 2 for all kinematics. Reliability was interpreted as excellent (>0.90), good (0.90-0.75), moderate (0.75-0.50), and poor (<0.50). Precision was calculated with the standard error of measurement (SEM). RESULTS: ICC and SEM demonstrated good reliability and precision for peak knee flexion (ICC2,1 = 0.914, SEM = 1.41). Reliability and precision were moderate for knee extension (ICC2,1 = 0.74, SEM = 1.21). Reliability was moderate for knee abduction (ICC2,1 = 0.54, SEM = 1.40), knee adduction (ICC2,1 = 0.59, SEM = 1.37), hip flexion (ICC2,1 = 0.70, SEM = 1.62), hip abduction (ICC2,1 = 0.61, SEM = 1.23), and hip adduction (ICC2,1 = 0.54, SEM = 1.75). Knee rotation, hip extension, and hip rotation demonstrated very poor reliability (ICC <0.50). CONCLUSION: Our results suggest that sagittal plane movements like knee extension and flexion demonstrate good to moderate reliability, however, they can still improve. Movements in the frontal plane are less reliable than the sagittal plane and the transverse plane. Possible solutions to improve reliability would include more cameras or positioning in a different pattern enabling a better view of the knee joint. Artificial Intelligence (AI) may need improvements, and future research should continue to investigate reliability and precision as improvements are made.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2024-09-16
DOI
https://doi.org/10.1249/01.mss.0001061248.35489.ee
Primary Topic
Winter Sports Injuries and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring The Test-retest Reliability Of Markerless Motion Capture For Outdoor Walking

Darren James, Taylor Jb, Hunter Hills, Ford KR et al.
1 links
Medicine & Science in Sports & Exercise
Winter Sports Injuries and Performance
article

Exploring The Test-retest Reliability Of Markerless Motion Capture For Outdoor Walking

Darren James, Taylor Jb, Hunter Hills, Ford KR, Pexa BS, Sydney Litwiller
article en

Abstract

BACKGROUND: Markerless motion capture is a rapidly advancing technology and has been tested indoors and proven reliable. However, there are no studies that have tested a portable markerless motion capture system outdoors and out of the lab setting. The purpose of this study is to determine test-retest reliability of knee kinematics using a portable markerless motion capture system during a walking test in healthy adults. METHODS: Twenty-one participants (6 M, 15F, age = 23.1 ± 1.8 years, height = 167.1 ± 7.8 cm, mass = 69.8 ± 23.1 kg) performed two walking tests each separated by five days. Participants walked at a comfortable pace for eight trials while being recorded at 60 Hz. After collection, video data was exported and reduced in a markerless motion capture software. Maximum and minimum knee and hip kinematics were collected during the first 50% of stance phase. Test-retest reliability was calculated with intraclass correlation coefficients (ICCs) between testing time 1 and time 2 for all kinematics. Reliability was interpreted as excellent (>0.90), good (0.90-0.75), moderate (0.75-0.50), and poor (<0.50). Precision was calculated with the standard error of measurement (SEM). RESULTS: ICC and SEM demonstrated good reliability and precision for peak knee flexion (ICC2,1 = 0.914, SEM = 1.41). Reliability and precision were moderate for knee extension (ICC2,1 = 0.74, SEM = 1.21). Reliability was moderate for knee abduction (ICC2,1 = 0.54, SEM = 1.40), knee adduction (ICC2,1 = 0.59, SEM = 1.37), hip flexion (ICC2,1 = 0.70, SEM = 1.62), hip abduction (ICC2,1 = 0.61, SEM = 1.23), and hip adduction (ICC2,1 = 0.54, SEM = 1.75). Knee rotation, hip extension, and hip rotation demonstrated very poor reliability (ICC <0.50). CONCLUSION: Our results suggest that sagittal plane movements like knee extension and flexion demonstrate good to moderate reliability, however, they can still improve. Movements in the frontal plane are less reliable than the sagittal plane and the transverse plane. Possible solutions to improve reliability would include more cameras or positioning in a different pattern enabling a better view of the knee joint. Artificial Intelligence (AI) may need improvements, and future research should continue to investigate reliability and precision as improvements are made.

Medicine & Science in Sports & ExerciseVol. 56(10S)
High Point University (US)
Openalex Percentile: Top 71%
Winter Sports Injuries and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.