Assessing The Validity Of A Core Temperature Monitoring Tool For Tactical Athletes

BACKGROUND: Core temperature information is important for guiding prevention and treatment measures. It is critical for those working in severe environments, such as firefighters, military, law enforcement, and construction and farm workers. Development of new physiological monitoring tools that are easy to use and provide reliable core temperature information is critical for heat injury prevention. An easily wearable sensor that correctly estimates core temperature could prevent heat injuries and deaths. The ThriveHRI sensor system is being developed for use in a smartwatch platform. The current study compared the ThriveHRI sensor/smartwatch to an Equivial LifeMonitor and a rectal thermistor. The purpose of this study was to determine if the ThriveHRI sensor system provides an accurate and precise estimate of core temperature at rest and during physical activity representing firefighter occupational tasks at elevated temperatures in healthy adults. METHODS: Twenty-five healthy, physically active adults between the ages of 19–45 years volunteered. Participants completed multiple rounds of deadlifting and treadmill walking in an environmental chamber set to 43.3 °C (115 °F) and 50% relative humidity. Core temperature was monitored continuously via a Datatherm rectal thermometer, Equivital Eq02 + LifeMonitor, and a ThriveHRI heat watch. RESULTS: No significant difference in accuracy between devices was found for any condition (ps > = 0.532). A significant difference in bias between devices was found for easy walking (t(21) = 5.55, p < 0.001, g = 1.01), deadlift (t(19) = 3.60, p = 0.002, g = 0.73), and treadmill (t(16) = 2.42, p = 0.028, g = 0.60). A significant difference in precision between devices was found for easy walking (t(21) = 4.23, p < 0.001, g = 1.21), but no significant difference in precision between devices was found for deadlift, or treadmill (ps ≥ 0.067). CONCLUSIONS: This study demonstrates that the agreeability between the Equivital EQ02+ LifeMonitor, ThriveHRI sensor, and the rectal thermometer remains consistent as core temperature increases and exposure to a heated environment is sustained. The ThriveHRI heat watch system may be an accurate and precise core temperature sensor system for use in the field.

Authors

Institutions

Publication Details

Journal
Medicine & Science in Sports & Exercise
Published
2024-09-16
DOI
https://doi.org/10.1249/01.mss.0001062448.81129.0f
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing The Validity Of A Core Temperature Monitoring Tool For Tactical Athletes

Nicholas C. Bordonie, Philip J. Agostinelli, JoEllen M. Sefton, Matthew D. Miller et al.
Medicine & Science in Sports & Exercise
Infrared Thermography in Medicine
article

Assessing The Validity Of A Core Temperature Monitoring Tool For Tactical Athletes

Nicholas C. Bordonie, Philip J. Agostinelli, JoEllen M. Sefton, Matthew D. Miller, Frances K. Neal
article en

Abstract

BACKGROUND: Core temperature information is important for guiding prevention and treatment measures. It is critical for those working in severe environments, such as firefighters, military, law enforcement, and construction and farm workers. Development of new physiological monitoring tools that are easy to use and provide reliable core temperature information is critical for heat injury prevention. An easily wearable sensor that correctly estimates core temperature could prevent heat injuries and deaths. The ThriveHRI sensor system is being developed for use in a smartwatch platform. The current study compared the ThriveHRI sensor/smartwatch to an Equivial LifeMonitor and a rectal thermistor. The purpose of this study was to determine if the ThriveHRI sensor system provides an accurate and precise estimate of core temperature at rest and during physical activity representing firefighter occupational tasks at elevated temperatures in healthy adults. METHODS: Twenty-five healthy, physically active adults between the ages of 19–45 years volunteered. Participants completed multiple rounds of deadlifting and treadmill walking in an environmental chamber set to 43.3 °C (115 °F) and 50% relative humidity. Core temperature was monitored continuously via a Datatherm rectal thermometer, Equivital Eq02 + LifeMonitor, and a ThriveHRI heat watch. RESULTS: No significant difference in accuracy between devices was found for any condition (ps > = 0.532). A significant difference in bias between devices was found for easy walking (t(21) = 5.55, p < 0.001, g = 1.01), deadlift (t(19) = 3.60, p = 0.002, g = 0.73), and treadmill (t(16) = 2.42, p = 0.028, g = 0.60). A significant difference in precision between devices was found for easy walking (t(21) = 4.23, p < 0.001, g = 1.21), but no significant difference in precision between devices was found for deadlift, or treadmill (ps ≥ 0.067). CONCLUSIONS: This study demonstrates that the agreeability between the Equivital EQ02+ LifeMonitor, ThriveHRI sensor, and the rectal thermometer remains consistent as core temperature increases and exposure to a heated environment is sustained. The ThriveHRI heat watch system may be an accurate and precise core temperature sensor system for use in the field.

Medicine & Science in Sports & ExerciseVol. 56(10S)
Auburn University (US)
Climate action
Openalex Percentile: Top 74%
Infrared Thermography in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.