Modeling of 10 kV Distribution Transformer Excited by Three-Phase Common Mode Transients

A 10-kV distribution transformer is exposed to the three-phase common mode transients due to the coupling between the three-phase transmission lines and transient electromagnetic disturbances. In this case, the multiconductor transmission line theory for a single winding is not sufficient to analyze the response of the transformer. In this article, a model of a 10-kV distribution transformer excited by three-phase common mode transients is proposed. The circuit diagram of the model is put forward based on the real scenario of the 10-kV distribution system excited by transient electromagnetic disturbances. The model takes into account the boundary conditions of the transformer windings, which enables the calculation of the responses of three phases simultaneously. The derivations are verified by an equivalent simulation method using PSpice. The test platform is built up and a 10-kV distribution transformer is studied for further verification. The model calculation results are compared with the test results, which is satisfactory.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Electromagnetic Compatibility
Published
2024-09-16
DOI
https://doi.org/10.1109/temc.2024.3454985
Citations
1
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling of 10 kV Distribution Transformer Excited by Three-Phase Common Mode Transients

Ning Dong, Zongyang Wang, Yan‐Zhao Xie, Yu-hao Chen
1 citations
IEEE Transactions on Electromagnetic Compatibility
Power Systems Fault Detection
0.33
article

Modeling of 10 kV Distribution Transformer Excited by Three-Phase Common Mode Transients

Ning Dong, Zongyang Wang, Yan‐Zhao Xie, Yu-hao Chen
article en
1 citations

Abstract

A 10-kV distribution transformer is exposed to the three-phase common mode transients due to the coupling between the three-phase transmission lines and transient electromagnetic disturbances. In this case, the multiconductor transmission line theory for a single winding is not sufficient to analyze the response of the transformer. In this article, a model of a 10-kV distribution transformer excited by three-phase common mode transients is proposed. The circuit diagram of the model is put forward based on the real scenario of the 10-kV distribution system excited by transient electromagnetic disturbances. The model takes into account the boundary conditions of the transformer windings, which enables the calculation of the responses of three phases simultaneously. The derivations are verified by an equivalent simulation method using PSpice. The test platform is built up and a 10-kV distribution transformer is studied for further verification. The model calculation results are compared with the test results, which is satisfactory.

IEEE Transactions on Electromagnetic CompatibilityVol. 67(2)
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Openalex Percentile: Top 42%
Power Systems Fault Detection
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.