Examining the role of density-driven transport on chlorinated vapor intrusion

This study investigates the influence of density-driven transport on chlorinated vapor intrusion through modeling and experiments. Density-driven transport involves downward vapor advection, potentially reducing vapor intrusion into buildings. A 1-D steady-state numerical model was developed using COMSOL Multiphysics, considering upward diffusion and downward density-driven advection in the subsoil and in the granular fill layer beneath building's foundations. Source vapor concentration and granular fill layer permeability emerged as the key factors affecting density-driven transport. Regardless of building characteristics, for permeabilities in the granular fill layer exceeding 10 −7 m 2 , density-driven transport is expected to become relevant at vapor concentrations of 1 mg m −3 , while for lower soil permeabilities (10 −8 -10 −10 m 2 ), density-driven transport impact is expected for vapor concentrations exceeding 1 g m −3 . The results of laboratory column trichloroethylene (TCE) diffusion tests through sand and gravel supported these findings, showing a vertical stratification of TCE vapor concentrations consistent with the model. The trends expected by modeling also align with the findings of different field studies, where the source to building attenuation factors (AF) were found to decrease with increasing source vapor concentration. These outcomes highlight that the common approach adopted for vapor intrusion screening from soil gas data based on default AF values independent of source vapor concentration, may potentially lead to an overestimation of indoor concentrations in the presence of high vapor concentrations and highly permeable soils. Given the use of permeable granular fill layers in building construction, this study underscores the importance of accounting for density-driven transport to improve the accuracy of vapor intrusion risk assessment. • Density-driven transport influence on chlorinated vapor intrusion was investigated. • TCE vapors diffusion tests were performed in sand and gravel-filled columns. • A numerical model considering density-driven for vapor transport was developed. • Subsurface vapor concentration and soil permeability emerged as determinant factors. • Neglecting density-driven effect may lead to overestimating vapor intrusion risk.

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2024-09-16
DOI
https://doi.org/10.1016/j.buildenv.2024.112096
Citations
2
Primary Topic
Groundwater flow and contamination studies
Type
article
Field-Weighted Citation Impact
0.41
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Examining the role of density-driven transport on chlorinated vapor intrusion

Iason Verginelli, Daniela Zingaretti, Clarissa Settimi
2 citations
Building and Environment
Groundwater flow and contamination studies
0.41
article

Examining the role of density-driven transport on chlorinated vapor intrusion

Iason Verginelli, Daniela Zingaretti, Clarissa Settimi
article en
2 citations

Abstract

This study investigates the influence of density-driven transport on chlorinated vapor intrusion through modeling and experiments. Density-driven transport involves downward vapor advection, potentially reducing vapor intrusion into buildings. A 1-D steady-state numerical model was developed using COMSOL Multiphysics, considering upward diffusion and downward density-driven advection in the subsoil and in the granular fill layer beneath building's foundations. Source vapor concentration and granular fill layer permeability emerged as the key factors affecting density-driven transport. Regardless of building characteristics, for permeabilities in the granular fill layer exceeding 10 −7 m 2 , density-driven transport is expected to become relevant at vapor concentrations of 1 mg m −3 , while for lower soil permeabilities (10 −8 -10 −10 m 2 ), density-driven transport impact is expected for vapor concentrations exceeding 1 g m −3 . The results of laboratory column trichloroethylene (TCE) diffusion tests through sand and gravel supported these findings, showing a vertical stratification of TCE vapor concentrations consistent with the model. The trends expected by modeling also align with the findings of different field studies, where the source to building attenuation factors (AF) were found to decrease with increasing source vapor concentration. These outcomes highlight that the common approach adopted for vapor intrusion screening from soil gas data based on default AF values independent of source vapor concentration, may potentially lead to an overestimation of indoor concentrations in the presence of high vapor concentrations and highly permeable soils. Given the use of permeable granular fill layers in building construction, this study underscores the importance of accounting for density-driven transport to improve the accuracy of vapor intrusion risk assessment. • Density-driven transport influence on chlorinated vapor intrusion was investigated. • TCE vapors diffusion tests were performed in sand and gravel-filled columns. • A numerical model considering density-driven for vapor transport was developed. • Subsurface vapor concentration and soil permeability emerged as determinant factors. • Neglecting density-driven effect may lead to overestimating vapor intrusion risk.

Building and EnvironmentVol. 266
University of Rome Tor Vergata (IT), Policlinico Tor Vergata (IT)
Openalex Percentile: Top 42%
Groundwater flow and contamination studies
0.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.