Improving Glucose Sensor Sensitivity with Dual Resonator Placement

This study presents a novel design of a planar microwave sensor for non-invasive blood glucose monitoring. The sensor utilizes two circular-shaped complementary split ring resonators (CSRRs) fabricated on a Rogers substrate with an epsilon value of 6.15 to achieve a characteristic impedance of 50 ohms. The impact of varying placement distances between the CSRRs on the sensor's sensitivity to different blood glucose concentrations is investigated. Simulation results show that a placement distance of 15 mm between the CSRRs yields the highest sensitivity. These findings highlight the importance of optimizing the proximity of the resonators for enhanced sensor performance. The proposed sensor design offers a promising approach for accurate and non-invasive glucose monitoring, con-tributing to the development of advanced biosensing technologies for diabetes management.

Authors

Institutions

Publication Details

Published
2024-08-11
DOI
https://doi.org/10.1109/mwscas60917.2024.10658923
Citations
6
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
1.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Glucose Sensor Sensitivity with Dual Resonator Placement

Ahmed Allam, Ahmed A. Zakaria, Tanemasa Asano, Adel B. Abdel-Rahman
6 citations
Microfluidic and Capillary Electrophoresis Applications
1.11
article

Improving Glucose Sensor Sensitivity with Dual Resonator Placement

Ahmed Allam, Ahmed A. Zakaria, Tanemasa Asano, Adel B. Abdel-Rahman
article en
6 citations

Abstract

This study presents a novel design of a planar microwave sensor for non-invasive blood glucose monitoring. The sensor utilizes two circular-shaped complementary split ring resonators (CSRRs) fabricated on a Rogers substrate with an epsilon value of 6.15 to achieve a characteristic impedance of 50 ohms. The impact of varying placement distances between the CSRRs on the sensor's sensitivity to different blood glucose concentrations is investigated. Simulation results show that a placement distance of 15 mm between the CSRRs yields the highest sensitivity. These findings highlight the importance of optimizing the proximity of the resonators for enhanced sensor performance. The proposed sensor design offers a promising approach for accurate and non-invasive glucose monitoring, con-tributing to the development of advanced biosensing technologies for diabetes management.

Kyushu University (JP), Egypt-Japan University of Science and Technology (EG)
Egypt-Japan University of Science and Technology
Affordable and clean energy
Openalex Percentile: Top 24%
Microfluidic and Capillary Electrophoresis Applications
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving Glucose Sensor Sensitivity with Dual Resonator Placement — Ahmed Allam, Ahmed A. Zakaria, et al. · (2024) | TGRS Research Map | TGRS