Ad hoc calibration of interferometric system for measuring nanometer-scale displacements induced by laser ultrasound

• Utilizes a 3 × 3 optical fiber coupler for stable, quantitative measurements without conventional calibration. • The system simplifies measurements, avoiding additional equipment and reducing complexity and cost. • Multiple data sets and coherent averaging enhance sensitivity and accuracy, achieving 0.14 nm resolution. • Capable of measuring small displacements, thickness and its variations in various applications. Laser Ultrasound (LUS) is commonly used in many fields including thickness measurement and defect inspection. In a conventional LUS system, a piezo-based transducer (PZT) is generally used for detecting the ultrasound echo waves, which requires direct contact with a specimen and thus prolongs measurement time when any lateral scanning is necessary. We present a novel non-contact interferometric system based on a 3 × 3 optical fiber coupler. Even though the 3 × 3 interferometric system works stably at any operating point and allows quantitative measurements, it is generally known that careful calibration is necessary before main measurements. Experimentally, it was observed that the surface displacement, induced by the ultrasound wave of LUS, of a cornea phantom was so minute that averaging was necessary. In this study, we discovered that by using the multiple data sets acquired for averaging, we could obtain the system ad hoc characteristic ellipse without performing the conventional calibration process. Furthermore, by utilizing coherent average we could extract the displacement with a 0.14 nm sensitivity. We could also measure the thickness variation, induced by ocular pressure, of the cornea phantom with a resolution of 4.3 μm by measuring the time of a round trip of the ultrasound wave. This straightforward system, composed solely of a 3 × 3 coupler, is expected to promise a compact and efficient solution to diverse applications.

Authors

Institutions

Publication Details

Journal
Optics & Laser Technology
Published
2024-09-16
DOI
https://doi.org/10.1016/j.optlastec.2024.111779
Citations
1
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ad hoc calibration of interferometric system for measuring nanometer-scale displacements induced by laser ultrasound

Taeil Yoon, Younggue Kim, Byeong Ha Lee
1 citations
Optics & Laser Technology
Optical measurement and interference techniques
0.25
article

Ad hoc calibration of interferometric system for measuring nanometer-scale displacements induced by laser ultrasound

Taeil Yoon, Younggue Kim, Byeong Ha Lee
article en
1 citations

Abstract

• Utilizes a 3 × 3 optical fiber coupler for stable, quantitative measurements without conventional calibration. • The system simplifies measurements, avoiding additional equipment and reducing complexity and cost. • Multiple data sets and coherent averaging enhance sensitivity and accuracy, achieving 0.14 nm resolution. • Capable of measuring small displacements, thickness and its variations in various applications. Laser Ultrasound (LUS) is commonly used in many fields including thickness measurement and defect inspection. In a conventional LUS system, a piezo-based transducer (PZT) is generally used for detecting the ultrasound echo waves, which requires direct contact with a specimen and thus prolongs measurement time when any lateral scanning is necessary. We present a novel non-contact interferometric system based on a 3 × 3 optical fiber coupler. Even though the 3 × 3 interferometric system works stably at any operating point and allows quantitative measurements, it is generally known that careful calibration is necessary before main measurements. Experimentally, it was observed that the surface displacement, induced by the ultrasound wave of LUS, of a cornea phantom was so minute that averaging was necessary. In this study, we discovered that by using the multiple data sets acquired for averaging, we could obtain the system ad hoc characteristic ellipse without performing the conventional calibration process. Furthermore, by utilizing coherent average we could extract the displacement with a 0.14 nm sensitivity. We could also measure the thickness variation, induced by ocular pressure, of the cornea phantom with a resolution of 4.3 μm by measuring the time of a round trip of the ultrasound wave. This straightforward system, composed solely of a 3 × 3 coupler, is expected to promise a compact and efficient solution to diverse applications.

Optics & Laser TechnologyVol. 181
Korea University (KR), Gwangju Institute of Science and Technology (KR), Korea University (JP)
Gwangju Institute of Science and Technology, Ministry of Trade, Industry and Energy
Affordable and clean energy
Openalex Percentile: Top 47%
Optical measurement and interference techniques
0.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.