Determination of tetramethylammonium hydroxide in air using ion chromatography or ultra-performance liquid chromatography - high-resolution mass spectrometry

Tetramethylammonium hydroxide (TMAH) is extensively utilized in the semiconductor and optoelectronic industries, serving as either a developer or an etchant. TMAH possesses acute toxicity and alkaline corrosiveness, having caused several fatal and injurious accidents in Taiwan. However, there is currently a lack of methods available for assessing TMAH exposure. This study developed a method involving sampling with quartz fiber filters followed by ultrasonic agitation in 10 mL mobile phase, filtering, and analysis using either ion chromatography (IC) or ultra-performance liquid chromatography - high-resolution mass spectrometry (UPLC-HRMS). Utilizing the characteristics of HRMS, the compound analyzed was identified as tetramethylammonium ion (TMA+) through mass spectrometry analysis. The method exhibits excellent trapping capacity and recovery rate. The linear range of TMA+ for IC is 0.3 to 100 μg/mL, with a correlation coefficient of R = 0.9998. The linear range of TMA+ for UPLC-HRMS is 0.002 to 1 μg/mL, with a correlation coefficient of R = 0.996. The recovery rates for IC and HRMS were 116.6% and 90.6%, with corresponding coefficient of variation (CV) of 2.25% and 3.53%, respectively. Samples can be stored at room temperature for 28 days. Verification of this method was conducted at the TMAH factory, and the air concentrations measured in the TMAH filling area were 3.29 and 4.75 μg/m3 from IC and UPLC-HRMS, respectively. This method will be applied in the on-site analysis of occupational hazards for operators in chemical plants, technology factories, and recycling plants, aiming to evaluate risk values to protect the safety and health of workers and prevent occupational diseases.

Authors

Institutions

Publication Details

Journal
Journal of Environmental Exposure Assessment
Published
2024-09-19
DOI
https://doi.org/10.20517/jeea.2024.15
Primary Topic
Environmental Chemistry and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of tetramethylammonium hydroxide in air using ion chromatography or ultra-performance liquid chromatography - high-resolution mass spectrometry

Pao‐Chi Liao, Yung‐Chieh Lin, Ping-Zu Hsiao, Chih‐Wei Chang et al.
Journal of Environmental Exposure Assessment
Environmental Chemistry and Analysis
article

Determination of tetramethylammonium hydroxide in air using ion chromatography or ultra-performance liquid chromatography - high-resolution mass spectrometry

Pao‐Chi Liao, Yung‐Chieh Lin, Ping-Zu Hsiao, Chih‐Wei Chang, Jen-Yi Hsu, Hsin-Lien Huang
article en

Abstract

Tetramethylammonium hydroxide (TMAH) is extensively utilized in the semiconductor and optoelectronic industries, serving as either a developer or an etchant. TMAH possesses acute toxicity and alkaline corrosiveness, having caused several fatal and injurious accidents in Taiwan. However, there is currently a lack of methods available for assessing TMAH exposure. This study developed a method involving sampling with quartz fiber filters followed by ultrasonic agitation in 10 mL mobile phase, filtering, and analysis using either ion chromatography (IC) or ultra-performance liquid chromatography - high-resolution mass spectrometry (UPLC-HRMS). Utilizing the characteristics of HRMS, the compound analyzed was identified as tetramethylammonium ion (TMA+) through mass spectrometry analysis. The method exhibits excellent trapping capacity and recovery rate. The linear range of TMA+ for IC is 0.3 to 100 μg/mL, with a correlation coefficient of R = 0.9998. The linear range of TMA+ for UPLC-HRMS is 0.002 to 1 μg/mL, with a correlation coefficient of R = 0.996. The recovery rates for IC and HRMS were 116.6% and 90.6%, with corresponding coefficient of variation (CV) of 2.25% and 3.53%, respectively. Samples can be stored at room temperature for 28 days. Verification of this method was conducted at the TMAH factory, and the air concentrations measured in the TMAH filling area were 3.29 and 4.75 μg/m3 from IC and UPLC-HRMS, respectively. This method will be applied in the on-site analysis of occupational hazards for operators in chemical plants, technology factories, and recycling plants, aiming to evaluate risk values to protect the safety and health of workers and prevent occupational diseases.

Journal of Environmental Exposure AssessmentVol. 3(3)
National Cheng Kung University (TW)
National Cheng Kung University
Openalex Percentile: Top 87%
Environmental Chemistry and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.