Calibration‐Free and Highly Sensitive Potentiometric Enzyme‐Based Biosensors

Enzyme-based amperometric biosensors have become popular for healthcare applications. However, they have been under constant pressure for technological innovation to improve their sensitivity and usability. An ideal biosensor has high sensitivity and calibration-free characteristics. This study aims to report enzyme-based glucose and lactate sensors that utilize a proposed "time-derivative of potential (dOCP/dt)" method, with a further aim being to prove theoretically and experimentally that dOCP/dt values are proportional to substrate concentration. High sensitivity is obtained regardless of the electrode size because the electrode potential is independent of the electrode area in the biosensor. Importantly, because the substrate diffusion determines the enzyme reaction rate on the sensors, the dOCP/dt biosensors can essentially eliminate external influences such as temperature and pH. The result is the successful realization of a biosensor that is calibration-free, making it a much more practical option.

Authors

Institutions

Publication Details

Journal
Small Methods
Published
2024-09-19
DOI
https://doi.org/10.1002/smtd.202401010
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration‐Free and Highly Sensitive Potentiometric Enzyme‐Based Biosensors

Kuniharu Takei, Nobuyuki Isshiki, Masafumi Takesue, Mitsuo Asai
2 citations
Small Methods
Analytical Chemistry and Sensors
0.58
article

Calibration‐Free and Highly Sensitive Potentiometric Enzyme‐Based Biosensors

Kuniharu Takei, Nobuyuki Isshiki, Masafumi Takesue, Mitsuo Asai
article en
2 citations

Abstract

Enzyme-based amperometric biosensors have become popular for healthcare applications. However, they have been under constant pressure for technological innovation to improve their sensitivity and usability. An ideal biosensor has high sensitivity and calibration-free characteristics. This study aims to report enzyme-based glucose and lactate sensors that utilize a proposed "time-derivative of potential (dOCP/dt)" method, with a further aim being to prove theoretically and experimentally that dOCP/dt values are proportional to substrate concentration. High sensitivity is obtained regardless of the electrode size because the electrode potential is independent of the electrode area in the biosensor. Importantly, because the substrate diffusion determines the enzyme reaction rate on the sensors, the dOCP/dt biosensors can essentially eliminate external influences such as temperature and pH. The result is the successful realization of a biosensor that is calibration-free, making it a much more practical option.

Small MethodsVol. 9(1)
Hokkaido University (JP), Kao Corporation (Japan) (JP)
Japan Society for the Promotion of Science, AIP Network Laboratory
Industry, innovation and infrastructure
Openalex Percentile: Top 38%
Analytical Chemistry and Sensors
0.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.