Exploring Metabolic Aberrations after Intracerebral Hemorrhage In Vivo with Deuterium Metabolic Spectroscopy Imaging
Aberrations in metabolism after intracerebral hemorrhage (ICH), particularly lactate metabolism, play a crucial role in the pathophysiology and patient outcome. To date, the evaluation of metabolism relies heavily on invasive methods such as microdialysis, restricting a comprehensive understanding of the metabolic mechanisms associated with ICH. This study proposes a noninvasive metabolic imaging method based on <sup>2</sup>H magnetic resonance spectroscopy and imaging (<sup>2</sup>H-MRS/MRSI) to detect metabolic changes after ICH in vivo. To overcome the low-sensitivity limitation of <sup>2</sup>H, we designed a new <sup>1</sup>H-<sup>2</sup>H double-resonance coil with <sup>2</sup>H-channel active detuning and proposed chemical shift imaging based on the balanced steady-state free precession method (CSI-bSSFP). Compared with the volume coil, the signal-to-noise ratio (SNR) of the new coil was increased by 4.5 times. In addition, the SNR of CSI-bSSFP was 1.5 times higher than that of conventional CSI. These two technologies were applied to measure lactate metabolic flux at different phases of ICH. The results show a higher lactate concentration in ICH rats than in control rats, which is in line with the increased expression of lactate dehydrogenase measured via immunohistochemistry staining (AUC<sub>Lac_area/Glc_area</sub>: control, 0.08 ± 0.02 vs ICH-3d, 0.39 ± 0.05 vs ICH-7d, 0.18 ± 0.02, <i>P</i> < 0.01; H-score: control, 126.4 ± 5.03 vs ICH-3d, 168.4 ± 5.71 vs ICH-7d,133.6 ± 7.70, <i>P</i> < 0.05). A higher lactate signal also appeared near the ICH region than in normal brain tissue. In conclusion, <sup>2</sup>H-MRS/MRSI shows potential as a useful method for in vivo metabolic imaging and noninvasive assessment of ICH.
Authors
- Qingjia Bao (ORCID: https://orcid.org/0000-0003-0940-2535)
- Zhi Zhang (ORCID: https://orcid.org/0000-0001-6256-9516)
- Maili Liu (ORCID: https://orcid.org/0000-0002-9359-915X)
- Mārtiņš Otikovs
- Lucio Frydman (ORCID: https://orcid.org/0000-0001-8208-3521)
- Xin Hua Zhou (ORCID: https://orcid.org/0000-0002-5580-7907)
- Jiazheng Wang (ORCID: https://orcid.org/0000-0003-1182-442X)
- Xin Cheng (ORCID: https://orcid.org/0000-0001-8680-578X)
- Xinjie Liu (ORCID: https://orcid.org/0009-0006-7871-6369)
- Zhuang Liu
- Chaoyang Liu (ORCID: https://orcid.org/0000-0003-2694-6040)
- Jie Wang (ORCID: https://orcid.org/0000-0003-2031-7227)
Institutions
- Chinese Academy of Sciences (CN)
- Philips (China) (CN)
- Wuhan Institute of Physics and Mathematics (CN)
- University of Chinese Academy of Sciences (CN)
- Weizmann Institute of Science (IL)
Publication Details
- Journal
- Analytical Chemistry
- Published
- 2024-09-19
- DOI
- https://doi.org/10.1021/acs.analchem.4c01999
- Citations
- 2
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.81
Funders
- National Natural Science Foundation of China
- Chinese Academy of Sciences
- National Key Research and Development Program of China