Optimization of the Pixel Design for Large Gamma Cameras Based on Silicon Photomultipliers

Most single-photon emission computed tomography (SPECT) scanners employ a gamma camera with a large scintillator crystal and 50-100 large photomultiplier tubes (PMTs). In the past, we proposed that the weight, size and cost of a scanner could be reduced by replacing the PMTs with large-area silicon photomultiplier (SiPM) pixels in which commercial SiPMs are summed to reduce the number of readout channels. We studied the feasibility of that solution with a small homemade camera, but the question on how it could be implemented in a large camera remained open. In this work, we try to answer this question by performing Geant4 simulations of a full-body SPECT camera. We studied how the pixel size, shape and noise could affect its energy and spatial resolution. Our results suggest that it would be possible to obtain an intrinsic spatial resolution of a few mm FWHM and an energy resolution at 140 keV close to 10%, even if using pixels more than 20 times larger than standard commercial SiPMs of 6 × 6 mm2. We have also found that if SiPMs are distributed following a honeycomb structure, the spatial resolution is significantly better than if using square pixels distributed in a square grid.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-09-19
DOI
https://doi.org/10.3390/s24186052
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of the Pixel Design for Large Gamma Cameras Based on Silicon Photomultipliers

Carolin Wunderlich, R. Paoletti, D. Guberman
1 links
Sensors
Medical Imaging Techniques and Applications
article

Optimization of the Pixel Design for Large Gamma Cameras Based on Silicon Photomultipliers

Carolin Wunderlich, R. Paoletti, D. Guberman
article en

Abstract

Most single-photon emission computed tomography (SPECT) scanners employ a gamma camera with a large scintillator crystal and 50-100 large photomultiplier tubes (PMTs). In the past, we proposed that the weight, size and cost of a scanner could be reduced by replacing the PMTs with large-area silicon photomultiplier (SiPM) pixels in which commercial SiPMs are summed to reduce the number of readout channels. We studied the feasibility of that solution with a small homemade camera, but the question on how it could be implemented in a large camera remained open. In this work, we try to answer this question by performing Geant4 simulations of a full-body SPECT camera. We studied how the pixel size, shape and noise could affect its energy and spatial resolution. Our results suggest that it would be possible to obtain an intrinsic spatial resolution of a few mm FWHM and an energy resolution at 140 keV close to 10%, even if using pixels more than 20 times larger than standard commercial SiPMs of 6 × 6 mm2. We have also found that if SiPMs are distributed following a honeycomb structure, the spatial resolution is significantly better than if using square pixels distributed in a square grid.

SensorsVol. 24(18)
University of Siena (IT), Institut Català de Ciències del Clima (ES), Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (IT), Universitat de Barcelona (ES)
Affordable and clean energy
Openalex Percentile: Top 74%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization of the Pixel Design for Large Gamma Cameras Based on Silicon Photomultipliers — Carolin Wunderlich, R. Paoletti, et al. · Sensors (2024) | TGRS Research Map | TGRS